  • The study evaluated the safety and effectiveness of ultrathin strut polymer-free sirolimus-eluting stents (PF-SES) in a diverse patient population undergoing percutaneous coronary interventions (PCI).
  • A total of 7243 patients were included, showing a low target lesion revascularization (TLR) rate of 2.2% and a stent thrombosis rate of 0.7% over 9-12 months of follow-up.
  • The results indicate that PF-SES are safe and effective, with particularly high procedural success rates in challenging cases like in-stent restenosis and isolated left main coronary artery disease.

Article Abstract

Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7034709PMC
http://dx.doi.org/10.1097/MD.0000000000019119DOI Listing

Publication Analysis

Top Keywords

polymer-free sirolimus
8
sirolimus eluting
8
procedural success
8
safety efficacy
8
unselected patient
8
tlr rate
8
coronary artery
8
myocardial infarction
8
rate
6
pf-ses
5

Similar Publications

Article Synopsis
  • Polymer-free sirolimus-eluting stents (PF-SES) offer advantages in drug delivery and healing compared to traditional polymer-coated sirolimus-eluting stents (SES), specifically for patients with type 2 diabetes and coronary artery disease.
  • A study involving 2,646 diabetes patients revealed that those receiving PF-SES showed better imaging results for stent healing, with lower rates of complications and higher minimum lumen area compared to SES patients.
  • The findings suggest that PF-SES may enhance long-term survival rates and clinical outcomes, indicating its potential as a preferable treatment option for this patient population.
View Article and Find Full Text PDF

Background: Patients undergoing primary percutaneous coronary intervention (PPCI) for ST-segment-elevation myocardial infarction (STEMI) have a high thrombotic burden and often have a high bleeding risk (HBR). Asian patients have different patterns of thrombotic and bleeding risk from other populations which may be particularly relevant in the setting of PPCI for STEMI.

Objectives: To assess the safety and efficacy of the polymer free biolimus coated coronary stent (PF-BCS, BioFreedom, Biosensors International) in Asian STEMI patients.

View Article and Find Full Text PDF
Article Synopsis
  • * Twenty patients were enrolled, and results after 8 months showed minimal in-stent late lumen loss (0.7 mm) and complete stent strut coverage, indicating successful healing.
  • * There were no adverse cardiovascular events reported within the same period, suggesting that the new stent design is safe and effective in treating coronary artery disease.
View Article and Find Full Text PDF
Article Synopsis
  • - Coronary artery disease (CAD) is a major health issue leading to high mortality rates, with drug-eluting stents (DES) and drug-coated balloons (DCB) being advanced treatment options that release drugs to prevent restenosis after angioplasty.
  • - A comprehensive review of various research articles highlights the evolution of DES and DCBs, addressing previous challenges like inflammation and stent thrombosis while improving biocompatibility with newer designs.
  • - Despite advancements in DES and DCB technologies, the review emphasizes that challenges still remain in clinical applications, affecting long-term treatment outcomes for patients with CAD.
View Article and Find Full Text PDF
Article Synopsis
  • The study analyzed the effects of coronary angioscopy (CAS) findings after the implantation of two types of stents: a polymer-free biolimus A9-coated stent (PF-BCS) and a durable polymer everolimus-eluting stent (DP-EES) in 99 patients, with evaluations done at 1 and 12 months post-implantation.
  • Results showed a decrease in thrombi and yellow plaque from 1 month to 12 months, with no new thrombi but some new yellow plaque observed in patients with DP-EES.
  • Key factors affecting thrombi development included management of diabetes, stent area, and stent coverage, highlighting that polymer
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!