A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A New Logging-While-Drilling Method for Resistivity Measurement in Oil-Based Mud. | LitMetric

A New Logging-While-Drilling Method for Resistivity Measurement in Oil-Based Mud.

Sensors (Basel)

State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University, Hangzhou 310027, China.

Published: February 2020

Resistivity logging is an important technique for identifying and estimating reservoirs. Oil-based mud (OBM) can improve drilling efficiency and decrease operation risks, and has been widely used in the well logging field. However, the non-conductive OBM makes the traditional logging-while-drilling (LWD) method with low frequency ineffective. In this work, a new oil-based LWD method is proposed by combining the capacitively coupled contactless conductivity detection (CD) technique and the inductive coupling principle. The CD technique is to overcome the electrical insulation problem of the OBM and construct an effective alternating current (AC) measurement path. Based on the inductive coupling principle, an induced voltage can be formed to be the indirect excitation voltage of the AC measurement path. Based on the proposed method, a corresponding logging instrument is developed. Numerical simulation was carried out and results show that the logging instrument has good measurement accuracy, deep detection depth and high vertical resolution. Practical experiments were also carried out, including the resistance box experiment and the well logging experiment. The results of the resistance box experiment show that the logging instrument has good resistance measurement accuracy. Lastly, the results of the well logging experiment indicate that the logging instrument can accurately reflect the positions of different patterns on the wellbore of the experimental well. Both numerical simulation and practical experiments verify the feasibility and effectiveness of the new method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070431PMC
http://dx.doi.org/10.3390/s20041075DOI Listing

Publication Analysis

Top Keywords

logging instrument
16
well logging
12
oil-based mud
8
logging
8
lwd method
8
inductive coupling
8
coupling principle
8
measurement path
8
path based
8
numerical simulation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!