Bioimpedance Spectroscopy of the Breast.

Lymphat Res Biol

Discipline of Physiotherapy, Faculty of Health Sciences, University of Sydney, Sydney, Australia.

Published: October 2020

Bioimpedance spectroscopy (BIS) measurements of breast lymphedema poses practical and technical challenges, in particular the determination of the resistance at zero frequency (R), the index of change in breast lymph content. Conventionally, R is calculated from data analysis by using a procedure eponymously known as Cole modeling, a method that is error-prone in the breast. The aim of this study was to evaluate polynomial curve fitting as an alternative analytic procedure. A sub-set of breast BIS measurements from 41 women with self-ascribed breast lymphedema obtained as part of the Breast Edema Exercise Trial (BEET) were analyzed by both the Cole and polynomial methods. BIS files for all subjects were able to be analyzed by using the polynomial method but only 73% and 88% of data files were analyzed for the affected and unaffected breasts, respectively, by using the Cole method. For those files that were capable of being analyzed by both methods, R values were highly correlated ( = 0.99) but with a small (1.6%) although statistically significant difference (paired test,  < 0.001) between methods. Analysis of BIS data using polynomial curve fitting is an acceptable and robust alternative to Cole modeling, particularly where impedance measurements are susceptible to technical sources of error of measurement. The small magnitude of difference observed between methods is unlikely to lead to misclassification of patients with lymphedema based on BIS assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1089/lrb.2019.0087DOI Listing

Publication Analysis

Top Keywords

bioimpedance spectroscopy
8
bis measurements
8
breast lymphedema
8
breast
7
spectroscopy breast
4
breast bioimpedance
4
spectroscopy bis
4
measurements breast
4
lymphedema poses
4
poses practical
4

Similar Publications

Purpose: This study compared %BFUS to %BF4C in young adult athletes.

Methods: University club sport athletes (86 women, 138 men) from a variety of teams participated. ADP, DXA, and bioimpedance spectroscopy were used to measure body volume, bone mineral content, and total body water, respectively, for the 4C model.

View Article and Find Full Text PDF

: Hemodialysis patients face a high mortality risk, requiring effective clinical assessments. In these patients, muscle wasting due to protein-energy wasting (PEW) leads to increased frailty, which is strongly associated with worse outcomes, including higher mortality. As muscle mass declines, so does functional capacity, making regular assessment of both muscle mass and function critical for prognostic evaluation.

View Article and Find Full Text PDF

A comprehensive review of computational diagnostic techniques for lymphedema.

Prog Biomed Eng (Bristol)

January 2025

Amrita Vishwa Vidyapeetham, Center for Wireless Networks & Applications (WNA), Amrita Vishwa Vidyapeetham Amritapuri, Kollam, India, Kollam, 690525, INDIA.

Lymphedema is localized swelling due to lymphatic system dysfunction, often affecting arms and legs due to fluid accumulation. It occurs in 20% to 94% of patients within 2 to 5 years after breast cancer treatment, with around 20% of women developing breast cancer-related lymphedema (BCRL). This condition involves the accumulation of protein-rich fluid in interstitial spaces, leading to symptoms like swelling, pain, and reduced mobility that significantly impact quality of life.

View Article and Find Full Text PDF

The placenta plays a critical role in nutrient and oxygen exchange during pregnancy, yet the effects of medicinal drugs on this selective barrier remain poorly understood. To overcome this, this study presents a cost-effective bioimpedance spectroscopy (BIS) system to assess tight junction integrity and monolayer formation in BeWo b30 cells, a widely used model of the multinucleated maternal-fetal exchange surface of the placental barrier. Cells were cultured on collagen-coated porous membranes and treated with forskolin to induce controlled syncytialization.

View Article and Find Full Text PDF

Prototype analysis of a low-power, small-scale wearable medical device.

J Electr Bioimpedance

January 2024

Electrical Engineering Department, State University of Santa Catarina, Santa Catarina, Brazil.

Wearable and portable devices are gaining significant popularity across consumer electronics as well as in medical and industrial fields. To ensure that these devices are both comfortable and appealing to users, they need to have low battery consumption and be compact in both size and weight. The EGluco project is focused on developing a wearable device for non-invasive blood glucose monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!