Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To investigate the impact of the retention system (screwed or cemented) of implant fixed dental prostheses (i-FDPs) on the peri-implant health, prosthesis' state, patient self-evaluation of functionality and aesthetics, and oral health-related quality of life (OHRQoL).
Methods: 35 participants were classified into two groups according to the retention system of their metal-ceramic i-FDPs. For the analysis of peri-implant health and prosthetic complications, the implant units were individually assessed. Group 1 (SPD; n = 22): implant units for screwed i-FDPs; and Group 2 (CPD; n = 36): implant units for cemented i-FDPs. Data related to socio-demographics, design and installation of the superstructures, peri-implant condition, prosthetic complications, functionality, and aesthetics, were gathered. Patients answered the Oral Health Impact Profile (OHIP-14sp) questionnaire. Descriptive and parametric probes were run to evaluate the impact scores considering the study variables (α = 0.05).
Results: The plaque index, gingival index, functionality, aesthetics, and global evaluation made by the patient recorded significantly better results for the SPD group. The most affected OHIP-14sp domain was 'Physical pain', followed by 'Psychological discomfort', and 'Functional limitation'. The subscales: 'Functional limitation', 'Physical disability', and 'Social disability', attributed significantly worst OHRQoL to CPD users.
Conclusion: A major presence of peri-implant disease, together with a worse functionality, aesthetics, and patient satisfaction were recorded in cemented i-FDPs with respect to the screwed ones.
Clinical Significance: The retention system of i-FDPs can impact the peri-implant health, the subjective functional and aesthetic evaluation of the restoration, and the patients' OHRQoL; the screw retention providing superior results than the cementation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jdent.2020.103298 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!