Introduction: The goal of this study was to evaluate distal femoral minimally invasive plate osteosynthesis (MIPO) from a distal medial approach by use of a pre-bent helical implant.

Material & Methods: A total of 18 lower extremities was evaluated. A 29.6 cm steel plate was constructed and pre-bent on bone specimens with a torsion of 55.7° A 5 cm incision was performed from the tip of the medial epicondyle alongside its centre in a proximal direction. The medial border of the vastus medialis was retracted anteriorly. The level of the proximal skin incision was determined using the length of the pre-bent plates. The proximal incision was performed at a length of 4 cm at the described height at a line between the lateral epicondyle and the tip of the greater trochanter. A raspatory was advanced beneath the vastus medialis in a proximal direction to create an extraperiosteal tunnel for plate insertion. The plate was fixed to the bone at its proximal and distal portion via screws. Following dissection, the distance between the nearest perforator to the proximal plate end was evaluated. The vertical distances between the medial border of the plate and the femoral artery and femoral nerve were measured at the level of the proximal plate end and at the level of the proximal margin of the vastoadductor membrane.

Results: The most proximal perforating artery was located at a mean distance of 20.15 mm starting from the proximal plate margin. The mean interval between the medial border of the plate at the level of its proximal tip and the femoral artery was 51.9 mm. The average distance between the femoral nerve and the medial border of the proximal part of the plate was 42.3 mm. Regarding the interval between the medial border of the plate and the femoral artery, this was at a mean of 40.5 mm at the level of the proximal margin of the vastoadductor membrane. During dissection, none of the specimens showed any lesions of the adjacent anatomical characteristics.

Conclusion: Our results indicate MIPO of the distal femur from a medial approach as a safe technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2020.02.051DOI Listing

Publication Analysis

Top Keywords

medial border
20
level proximal
20
proximal plate
16
proximal
13
plate
12
border plate
12
femoral artery
12
medial
9
minimally invasive
8
plate osteosynthesis
8

Similar Publications

Previous research has shown that smoking tobacco is associated with changes or differences in brain volume and cortical thickness, resulting in a smaller brain volume and decreased cortical thickness in smokers compared with non-smokers. However, the effects of smokeless tobacco on brain volume and cortical thickness remain unclear. This study aimed to investigate whether the use of shammah, a nicotine-containing smokeless tobacco popular in Middle Eastern countries, is associated with differences in brain volume and thickness compared with non-users and to assess the influence of shammah quantity and type on these effects.

View Article and Find Full Text PDF

Background: Involution or aging is the most common cause of lower eyelid entropion (in-turning of eyelid margin) in the elderly population. Various pathomechanisms have been postulated for its occurrence. Aging leads to laxity of tissues and loss of muscle tone.

View Article and Find Full Text PDF

Fractures of the humerus are common on the midshaft of the bone, often causing injury to the nutrient artery. Successful fracture repair and healing requires preservation of the blood supply to the long bones which is conveyed through the nutrient foramina (NF). The topography of long bone NF varies in different populations.

View Article and Find Full Text PDF

Interobserver reliability of Pirani scoring for idiopathic clubfoot in walking-age children.

J Pediatr Orthop B

January 2025

Department of Paediatric Orthopaedics, Chacha Nehru Bal Chikitsalaya, Delhi, India.

Pirani scoring system is one of the most commonly used tools to assess the initial deformity, monitor the treatment progression, and identify relapse in clubfoot. The method has been demonstrated to correlate well with the sequential correction of deformity for children under age 1 year. We conducted a study to examine the interobserver reliability of Pirani scores in children of walking-age.

View Article and Find Full Text PDF

L-ICG as an optical agent to improve intraoperative margin detection in breast-conserving surgery: a prospective study.

Breast Cancer Res Treat

January 2025

Diagnosis and Treatment Center of Breast Diseases, Shantou Central Hospital, Waima Road 114, Jinping District, Shantou, 515041, China.

Purpose: Precise tumor excision is important in breast-conserving surgery (BCS). This study explores the safety and accuracy of fluorescence image-guided BCS (FIGS) using a lidocaine mucilage-ICG compound (L-ICG).

Methods: 54 patients who underwent BCS from August 2020 to September 2023 were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!