Automation of boron chromatographic purification for δ B analysis of coral aragonite.

Rapid Commun Mass Spectrom

School of Ocean and Earth Science, National Oceanography Centre Southampton, University of Southampton, Southampton, SO14 3ZH, UK.

Published: June 2020

AI Article Synopsis

  • The boron isotope ratio of coral carbonates is crucial for detecting past pH changes, requiring high precision and accuracy in measurements using MC-ICPMS.
  • The study used the automated prepFAST-MC method for sample purification, optimizing conditions and testing its effects on accuracy with various coral and standard samples.
  • Results show that prepFAST-MC produces reliable δ B values with negligible blank contamination and efficiency in matrix removal, validating its effectiveness compared to traditional methods.

Article Abstract

Rationale: To detect the small changes in past pH the boron isotope ratio of coral carbonates, expressed as the δ B value, needs to be both precise and accurate (2sd <<1‰). Boron measurements by Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) require the boron to be carefully purified before analysis, which is time consuming, and requires specialist training. Here, we use the prepFAST-MC method that enables the automatic extraction of B (up to 25 ng load) from a CaCO matrix.

Methods: Samples were purified using the prepFAST-MC automated system with a ~25-μL column of Amberlite IRA743 resin. Boron isotope measurements were performed by MC-ICPMS. The effects of matrix load, speed of sample loading onto the column, and blank contamination were tested to evaluate the effects on the purification process. The optimised protocol was tested on various standards and samples of aragonite corals.

Results: The blank contribution for the approach is ~60 pg and is negligible given our sample size (<0.2% sample size). Efficiency of matrix removal is demonstrated with the addition of up to 1.6 mg of dissolved low-B calcium carbonate to NIST SRM 951 with no impact on the accuracy of δ B values. The Japanese Geological Survey Porites reference material JCp-1, boric acid standard NIST SRM 951, and seawater, all processed on the prepFAST-MC system, give δ B values within error of literature values (δ B = 24.31 ± 0.20‰ (2sd, n = 20); δ B = -0.02 ± 0.15‰ (2sd, n = 13) and δ B = 39.50 ± 0.06‰ (2sd, n = 2)). Results obtained from the coral Siderastrea siderea purified with the prepFAST-MC system show an average offset from the manual ion-exchange protocols of Δδ B = 0.01 ± 0.28‰ (2sd, n = 12).

Conclusions: Our study demonstrates the capacity of the prepFAST-MC method to generate accurate and reproducible δ B values for a range of materials, without fractionation, with efficient matrix removal and with negligible blank contribution.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.8762DOI Listing

Publication Analysis

Top Keywords

automation boron
4
boron chromatographic
4
chromatographic purification
4
purification analysis
4
analysis coral
4
coral aragonite
4
aragonite rationale
4
rationale detect
4
detect small
4
small changes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!