Total body irradiation (TBI) is used prior to bone marrow transplantation as part of the conditioning regimen in selected patients. A linear accelerator-based technique was used at our treatment centre between June, 2004 and August, 2015. Patients were treated supine with extended source-to-surface distance (SSD) lateral fields, and prescription dose was 12 Gy delivered in six fractions, two fractions per day. Dose was prescribed to midplane at the level of the umbilicus and monitor units were calculated manually based on measured beam data. Dose variation within 10% of the prescribed midplane dose is considered acceptable for TBI treatment. This was achieved in our clinic by using compensators to account for missing tissue in the head and neck and lower leg regions. Lung attenuators were routinely used to correct for internal inhomogeneity, which resulted from low density lung tissue. The purpose of this study was to determine whether dose variation was within acceptable limits for these patients as part of a quality assurance process. Following chart review, 129 patients who received six-fraction TBI from 2004 to 2015 were included in this study. Patients receiving single fraction treatment were excluded. Metal oxide semiconductor field effect transistors (MOSFET) dosimetry was used to measure surface dose at four or five locations during patients' first fraction of TBI. Dosimetry was repeated during the second fraction for any site with variation greater than 10%. Statistical analysis was carried out on patient data, diagnosis and dosimetry measurements. Of the 129 patients who met the inclusion criteria, 50 were diagnosed with acute myelogenous leukemia, 30 with acute lymphoblastic leukemia and 11 with chronic myelogenous leukemia. The rest of the patients were diagnosed with lymphoma or myelodysplastic syndromes. The mean percent variation in dosimetry measurements taken at the specific locations ranged between 3.5% and 8.3%. The highest variation was found in measurements performed on the cheek. A high percentage of all dosimetry readings (85.5%) was within the acceptable range of +10% from the expected value. The highest number of individual readings taken at a specific location that fell outside this range were found at the cheek. We conclude that the linear accelerator delivered TBI at our centre meets the acceptable limits of dose variation over an 11-year period.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7003717PMC
http://dx.doi.org/10.7759/cureus.6900DOI Listing

Publication Analysis

Top Keywords

dose variation
12
patients
8
total body
8
body irradiation
8
quality assurance
8
prescribed midplane
8
acceptable limits
8
129 patients
8
myelogenous leukemia
8
dose
6

Similar Publications

Unlabelled: Studies have suggested that phytochemicals in green tea have systemic anti-inflammatory and neuroprotective effects. However, the mechanisms behind these effects are poorly understood, possibly due to the differential metabolism of phytochemicals resulting from variations in gut microbiome composition. To unravel this complex relationship, our team utilized a novel combined microbiome analysis and metabolomics approach applied to low complexity microbiome (LCM) and human colonized (HU) gnotobiotic mice treated with an acute dose of powdered matcha green tea.

View Article and Find Full Text PDF

Background: Curcumin is a polyphenolic compound derived from the food spice turmeric that has received interest from the medical and scientific world for its role in the management of several conditions. Clinical studies, in humans, have shown that ingested Curcumin is safe even at high doses (12 g/day), but it has poor bioavailability primarily due to poor absorption and rapid metabolism and elimination. Several strategies have been implemented to improve the bioavailability of Curcumin, for example, the combination of piperine in a complex with Curcumin, or the usage of formulations with phospholipid or liposomal complexes.

View Article and Find Full Text PDF

Background And Purpose:  Computed tomography radiostereometric analysis (CT-RSA) assesses implant micromovements using low-dose CT scans. We aimed to investigate whether CT-RSA is comparable to marker-based radiostereometric analysis (RSA) measuring early femoral head migration in cemented stems. We hypothesized that CT-RSA is comparable to marker-based RSA in evaluating femoral head subsidence.

View Article and Find Full Text PDF

Biomarkers.

Alzheimers Dement

December 2024

Beckman Coulter Inc., Chaska, MN, USA.

Background: The analytical performance characteristics for the plasma Glial Fibrillary Acidic Protein (GFAP) immunoassay currently under development on Beckman Coulter, Inc. Access2™ and DxI9000™ analyzers is described. Blood GFAP levels may be indicative of the extent of neurologic injury in diseases such as TBI and stroke and maybe used as a marker of disease progression in other diseases such as multiple sclerosis.

View Article and Find Full Text PDF

The aim of this study was to present a nationwide survey on the specialist's attitudes towards stereotactic body radiotherapy (SBRT) combined with poly (ADP-ribose) polymerase inhibitors (PARPi) with oligometastatic/oligoprogressive/oligorecurrent ovarian cancer (oMPR-OC) patients. The 19-item questionnaire was developed by specialists and distributed online. Replies were stratified by categories and analyzed using descriptive statistics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!