A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel functional C1 inhibitor activity assay in dried blood spot for diagnosis of Hereditary angioedema. | LitMetric

A novel functional C1 inhibitor activity assay in dried blood spot for diagnosis of Hereditary angioedema.

Clin Chim Acta

Clinical Biomarker Innovation and Development, Takeda Pharmaceuticals International Co., 125 Binney Street, Cambridge, MA, USA. Electronic address:

Published: May 2020

Background: Hereditary angioedema (HAE) is a rare genetic disease caused by deficiency or dysfunction of C1 esterase inhibitor (C1-INH). Timely and accurate diagnosis is an ongoing challenge. Measurement of plasma C1-INH activity is currently the critical standard test. We describe a novel and highly robust point-of-care assay to quantify C1-INH activity in dried blood spot (DBS).

Methods: C1-INH was extracted from 3 mm punches of DBS samples and incubated with excess amount of C1 esterase (C1s). The mixture was subsequentially incubated with C1s substrate, followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) quantitation of the enzyme reaction product.

Results: The assay was validated within a quantification range from 100 to 1500 mU/mL. The intra-day precision and accuracy ranged from 4.0% to 11.6% and -11.1% to -2.1%, and the inter-day precision and accuracy were 8.1-13.1% and -10.3% to 0.9%, respectively. Normal C1-INH activity (n = 103) ranged from 311 to 1090 mU/mL, whereas 23 out of 24 HAE patients exhibited C1-INH activity lower than 100 mU/mL.

Conclusion: DBS specimen collection for measurement of functional C1-INH activity in a physician's office is straightforward and not limited by logistic considerations and therefore, appropriate for the diagnosis of HAE in high throughput diagnostic laboratories.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2020.02.010DOI Listing

Publication Analysis

Top Keywords

c1-inh activity
20
dried blood
8
blood spot
8
hereditary angioedema
8
precision accuracy
8
c1-inh
7
activity
6
novel functional
4
functional inhibitor
4
inhibitor activity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!