Design of a Carrier Wave for Capacitive Transducer with Large Dynamic Range.

Sensors (Basel)

TianQin Research Center for Gravitational Physics and School of Physics and Astronomy, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, China.

Published: February 2020

Capacitive transducers are widely used in fundamental physics experiments, seismology, Earth or planetary observations, and space scientific and technical applications because of their high precision, simple structure, and compatibility with various measurements. However, in real applications, there is a trade-off between their resolution and dynamic range. Therefore, this paper is aimed at enlarging the dynamic range while ensuring high resolution. In this paper, a noise analysis of a capacitive transducer is presented, which shows that the amplitude noise of the carrier wave is the main limiting factor. Hence, a new method of generating a carrier wave with lower-amplitude noise is proposed in the paper. Based on the experimental verification, it is found that the carrier wave produced through the new method performed significantly better than the typical digital carrier wave when they were compared in the same sensing circuit. With the carrier wave produced through the new method, the dynamic range of the capacitive transducer can reach 120.7 dB, which is 18.3 dB greater than for the typical direct digital synthesis (DDS) method. In addition, the resolution of the carrier wave is mainly limited by the voltage reference components.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7070244PMC
http://dx.doi.org/10.3390/s20040992DOI Listing

Publication Analysis

Top Keywords

carrier wave
28
dynamic range
16
capacitive transducer
12
range capacitive
8
wave produced
8
produced method
8
wave
7
carrier
6
design carrier
4
capacitive
4

Similar Publications

Measurement and spectral analysis of medical shock wave parameters based on flexible PVDF sensors.

Phys Eng Sci Med

January 2025

School of Biological Science and Medical Engineering, Beihang University, 37 Xueyuan Road, Haidian District, Beijing, 100191, China.

Extracorporeal shock wave therapy (ESWT) achieves its therapeutic purpose mainly through the biological effects produced by the interaction of shock waves with tissues, and the accurate measurement and calculation of the mechanical parameters of shock waves in tissues are of great significance in formulating the therapeutic strategy and evaluating the therapeutic effect. This study utilizes the approach of implanting flexible polyvinylidene fluoride (PVDF) vibration sensors inside the tissue-mimicking phantom of various thicknesses to capture waveforms at different depths during the impact process in real time. Parameters including positive and negative pressure changes (P, P), pulse wave rise time ([Formula: see text]), and energy flux density (EFD) are calculated, and frequency spectrum analysis of the waveforms is conducted.

View Article and Find Full Text PDF

The steep temperature gradient near the bottom of the mantle is known to generate a negative correlation between the shear wave velocity ( ) and the depth in most regions of the D″ layer, as detected by seismological observations. However, increasing with depth is observed at the D″ layer beneath Central America, where the Farallon slab sinks, and the origin of this anomaly has not been well constrained. Here, we calculate the thermoelastic constants and obtain the elastic wave velocities of hydrous phase H with various Al contents and cation configurations, which may act as a water carrier to the D″ layer.

View Article and Find Full Text PDF

Reducing Nonradiative Recombination in Halide Perovskites through Appropriate Band Gaps and Heavy Atomic Masses.

J Phys Chem Lett

January 2025

State Key Laboratory of Organic Electronics and Information Displays, Nanjing University of Posts & Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.

Halide perovskite optoelectronic devices achieve high energy conversion efficiencies. However, their efficiency decreases significantly with an increase in temperature. This decline is likely caused by changes in nonradiative recombination and electron-phonon coupling, which remain underexplored.

View Article and Find Full Text PDF

Cerebral Microbleeds and Amyloid Pathology Estimates From the Amyloid Biomarker Study.

JAMA Netw Open

January 2025

Alzheimer Center Limburg, Department of Psychiatry and Neuropsychology, School for Mental Health and Neuroscience, Maastricht University, Maastricht, the Netherlands.

Importance: Baseline cerebral microbleeds (CMBs) and APOE ε4 allele copy number are important risk factors for amyloid-related imaging abnormalities in patients with Alzheimer disease (AD) receiving therapies to lower amyloid-β plaque levels.

Objective: To provide prevalence estimates of any, no more than 4, or fewer than 2 CMBs in association with amyloid status, APOE ε4 copy number, and age.

Design, Setting, And Participants: This cross-sectional study used data included in the Amyloid Biomarker Study data pooling initiative (January 1, 2012, to the present [data collection is ongoing]).

View Article and Find Full Text PDF

Improving the sensitivity of biosensor has always the major challenge to measure lower detection concentration of biological samples. In this paper, a novel optical fiber surface plasmon resonance (SPR) biosensor based on TiC MXene/GNRs synergistically highly enhanced sensitivity was proposed. The TiC MXene and GNRs were coated on the optical fiber sensing probe by the electrostatic layer-by-layer (ELBL) assembly method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!