For permanent magnet synchronous motor drives, the difficulty of parameter tuning of nonlinear active disturbance rejection control (ADRC) current controller is the bottleneck for its application. This paper proposes a measurement delay compensated linear ADRC (LADRC), and a simple tuning method for LADRC's parameters is presented. Firstly, an ideal model without resistance is acquired, because the current coupling terms, dead-time effects, and motor parameter variations are estimated and canceled out by an linear extended state observer. Secondly, an improved LADRC considering time delay of current measurement is developed. It eliminates unmatched disturbance compensation caused by measurement delay. And frequency responses of current closed-loop gain and disturbance suppression are evaluated. Then, based upon the frequency characteristics of the LADRC controller, a simple tuning method founded on desired frequency bandwidth is presented. It is convenient to be implemented. Finally, experimental results demonstrate that the proposed method is effective.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.isatra.2020.01.027DOI Listing

Publication Analysis

Top Keywords

measurement delay
12
tuning method
12
delay compensated
8
current controller
8
parameter tuning
8
simple tuning
8
current
5
measurement
4
ladrc
4
compensated ladrc
4

Similar Publications

Purpose: The purpose of the project was to reduce the occurrence of nonclinical delays resulting in increased postanesthesia care unit length of stay for carpal tunnel release patients in an ambulatory orthopedic surgery center through the implementation of new workflow processes in both the preoperative and postoperative phases of care.

Design: Pre-post design, with data being analyzed both before and after implementation of evidence-based quality improvement measures to assess for effectiveness of project interventions.

Methods: At the ambulatory orthopedic surgery center, preintervention data were gathered for 6 months on carpal tunnel release patients (n = 185) to determine the root causes of discharge delays (January to June 2023).

View Article and Find Full Text PDF

A Robust Method for Validating Orientation Sensors Using a Robot Arm as a High-Precision Reference.

Sensors (Basel)

December 2024

Antal Bejczy Center for Intelligent Robotics, Obuda University, 1034 Budapest, Hungary.

This paper presents a robust and efficient method for validating the accuracy of orientation sensors commonly used in practical applications, leveraging measurements from a commercial robotic manipulator as a high-precision reference. The key concept lies in determining the rotational transformations between the robot's base frame and the sensor's reference, as well as between the TCP (Tool Center Point) frame and the sensor frame, without requiring precise alignment. Key advantages of the proposed method include its independence from the exact measurement of rotations between the reference instrumentation and the sensor, systematic testing capabilities, and the ability to produce repeatable excitation patterns under controlled conditions.

View Article and Find Full Text PDF

We demonstrate high-resolution single-pixel imaging (SPI) in the visible and near-infrared wavelength ranges using an SPI framework that incorporates a novel, dedicated sampling scheme and a reconstruction algorithm optimized for the rapid imaging of highly sparse scenes at the native digital micromirror device (DMD) resolution of 1024 × 768. The reconstruction algorithm consists of two stages. In the first stage, the vector of SPI measurements is multiplied by the generalized inverse of the measurement matrix.

View Article and Find Full Text PDF

The precise localization of epileptic foci with the help of EEG or iEEG signals is still a clinical challenge with current methodology, especially if the foci are not close to individual electrodes. On the research side, dipole reconstruction for focus localization is a topic of recent and current developments. Relatively low numbers of recording electrodes cause ill-posed and ill-conditioned problems in the inversion of lead-field matrices to calculate the focus location.

View Article and Find Full Text PDF

This article presents a laboratory device by which the course of two signals can be detected using two types of sensors-strain gauges and the DEWESoft DS-NET measuring apparatus. The values of the coefficient of friction of the brake lining when moving against the rotating shell of the brake drum were determined from the physical quantities sensed by tensometric sensors and transformed into electrical quantities. The friction coefficient of the brake lining on the circumference of the rotating brake disc shell can be calculated from the known values measured by the sensors, the design dimensions of the brake, and the revolutions of the rotating parts system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!