Evaluation of computed tomography arterial portography scan timing using different bolus tracking methods.

Radiol Phys Technol

Division of Radiology and Nuclear Medicine, Sapporo Medical University Hospital, 291, West-16, South-1, Chuo-ku, Sapporo, Hokkaido, 060-8543, Japan.

Published: March 2020

Computed tomography arterial portography (CTAP) is widely used with a fixed scan timing and contrast medium quantity; however, these parameters are not necessarily optimal. In this study, CTAP scan timing was analyzed by different bolus tracking methods to monitor the inflow of the contrast medium in real-time. A total of 249 patients who underwent CTAP were assessed. In 30 patients, the CTAP scanning began 33 s after contrast medium injection started (fixed method). In 74 patients, the regions of interest (ROIs) were established at two places in the inferior vena cava above the hepatic vein (inferior vena cava-ROI method). In 145 patients, the ROI was established at two places in the liver parenchyma (liver parenchyma-ROI method). Scan timing was considered appropriate when the difference in the CT value between the hepatic and portal veins approached 0; this was observed significantly more with the liver parenchyma-ROI method than with the other methods. CTAP scan timing with the liver parenchyma-ROI method was better than that with the fixed and inferior vena cava-ROI methods.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-020-00556-5DOI Listing

Publication Analysis

Top Keywords

scan timing
20
contrast medium
12
inferior vena
12
liver parenchyma-roi
12
parenchyma-roi method
12
computed tomography
8
tomography arterial
8
arterial portography
8
bolus tracking
8
tracking methods
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!