Purpose: The purpose of this study was to evaluate the antithrombogenic effects of poly-2-methoxyethylacrylate (PMEA) coating applied to the internal surfaces of the port-catheter system to prevent thrombotic occlusion.

Materials And Methods: PMEA coating was applied to the inner surfaces of the entire system, including the chamber, catheter, and connecting stem. PMEA-coated and uncoated port-catheter systems were each filled with fresh human blood for 1 or 3 h and then flushed with saline. Volumes of residual thrombi in the system and protein in the catheter were then compared.

Results: Saline flushing of the PMEA-coated port-catheter system expelled all visually recognizable thrombi, leaving no unremovable adhesions. In contrast, the uncoated port showed thrombi adherent to the inner surfaces and incomplete expulsion with flushing. Mean (± standard deviation) residual thrombus mass was significantly lower in PMEA-coated port-catheter systems (20.5 ± 6.2 mg) than in uncoated systems (230.3 ± 92.5 mg; p < 0.01). Mean residual protein was likewise significantly lower in PMEA-coated systems (20.5 ± 6.2 mg) than in uncoated systems (230.3 ± 92.5 mg; p < 0.01).

Conclusions: PMEA coating on a central venous port-catheter system decreased accumulation and facilitated flushing of thrombi from the system by flushing, as compared with the uncoated system. PMEA-coated central venous port-catheter systems appear relatively antithrombotic compared to uncoated systems.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-020-02408-6DOI Listing

Publication Analysis

Top Keywords

port-catheter system
12
pmea coating
8
coating applied
8
inner surfaces
8
port-catheter systems
8
pmea-coated port-catheter
8
port-catheter
5
system
5
assessment antithrombogenicity
4
antithrombogenicity poly-2-methoxyethylacrylate-coated
4

Similar Publications

This study aims to assess the clinical efficacy and feasibility of the Perclose ProGlide Suture-Mediated Closure System (Abbott Vascular, Redwood City, CA, USA) for transbrachial access. A total of 100 patients from July 2020 to December 2023 were included in this retrospective study. Among them, 40 patients underwent ProGlide-guided suture closure following brachial artery (BA) puncture, while 60 patients received traditional manual compression.

View Article and Find Full Text PDF

Introduction: Nicaragua is a Central American country with a high prevalence of patients with chronic kidney disease, particularly among young men. This is largely attributable to Mesoamerican nephropathy, a form of interstitial nephritis that predominantly affects young agricultural workers. While the majority of patients have access to chronic dialysis programs, a very small number have an option of receiving a renal transplant.

View Article and Find Full Text PDF

Remote-Controlled and Teleoperated Systems: Taking Robotic Image Guided Interventions to the Next Stage.

Tech Vasc Interv Radiol

December 2024

Division of Vascular and Interventional Radiology, Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD. Electronic address:

Remote-controlled and teleoperated robotic systems mark transformative advancements in interventional radiology (IR), with the potential to enhance precision, reduce radiation exposure, and expand access to care. By integrating robotic devices with imaging guidance, these systems enable precise instrument placement and navigation, thereby improving the efficacy and safety of minimally invasive procedures. Remote-controlled and teleoperated robotic systems-operated by clinicians using control interfaces from within or adjacent to the procedure room-are being adopted for both percutaneous and endovascular interventions.

View Article and Find Full Text PDF

Introduction: Acute kidney injury (AKI) is a common complication of acute respiratory distress syndrome (ARDS) and multiple organ dysfunction syndrome (MODS) in patients receiving extracorporeal membrane oxygenation (ECMO) support, leading to requirement of continuous renal replacement therapy (CRRT) in 70% of ECMO patients. Parallel arrangement of CRRT and ECMO circuits is common in adult patients. However, CRRT may also be integrated directly into the ECMO circuit.

View Article and Find Full Text PDF

Background: Patients in many underserved geographies lack access to invasive coronary angiography (ICA).

Objectives: This preclinical study explored the feasibility of telerobotic ICA between separate continents.

Methods: Using a novel robotic system, attempts were made to navigate a magnetic guidewire and diagnostic catheter from the aortic arch into a target coronary artery ostium in a fluid-filled cardiac model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!