  • The study investigated the relationship between airborne particle counting and biocontamination in HEPA-filtered hospital rooms over two periods from 2016 to 2018.
  • During the training phase, an association was identified, with calculated areas under the ROC curve (aROC) indicating the effectiveness of different particle sizes in detecting contamination.
  • The findings suggest that airborne particle counting can serve as a quick and useful method for early detection of biocontamination in controlled environments.

Article Abstract

Our aim was to assess whether airborne particle counting is an immediate indicator of biocontamination in controlled environment rooms with HEPA filters in a hospital. A prospective study was carried out in a tertiary care hospital between 2016 and 2018. The study was divided in two periods and the measurements were performed in different controlled environment rooms with HEPA filters. The Environmental Biosafety Criterion (EBC) was defined as the absence of fungal and bacterial contamination. In the training period, the area under the ROC curve (aROC) of airborne particle counting and EBC was calculated for each particle size as well as the cut-off points that optimize the combination of sensitivity and specificity in the association between them. aROC is created by plotting sensitivity against 1-specificity. In the testing period, the cut-off points previously selected were validated. 328 measurements were carried out in the training period and 301 in the testing period. In the training period, an association was found between airborne particle counting and EBC. An aROC = 0.760, 95% Confidence Interval (95% CI) 0.695-0.825 was observed for 0.3 µm particles; an aROC = 0.797 (95% CI 0.734-0.860) for 0.5 µm particles; and an aROC = 0.751 (95% CI 0.673-0.829) for 5 µm particles. The cut-off points that optimized the combination of sensitivity and specificity were 9.0 × 10 for 0.3 µm particles, 3.6 × 10 particles for 0.5 µm, and 3.2 × 10 particles for 5 µm. In the testing period, the previous cut-off points were validated. We conclude that airborne particle counting is a useful, immediate, and preliminary measure to identify the presence of biocontamination in controlled environment rooms with HEPA filters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7018744PMC
http://dx.doi.org/10.1038/s41598-020-59367-8DOI Listing

Publication Analysis

Top Keywords

airborne particle
20
particle counting
20
controlled environment
16
environment rooms
16
rooms hepa
16
hepa filters
16
cut-off points
16
training period
12
testing period
12
biocontamination controlled
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!