Primary stability of self-tapping dual etched implants.

Minerva Stomatol

Center of Studies for Restorative Dentistry, Faculty of Dentistry, MARA Technology University, Jalan Hospital, Sungai Buloh, Malaysia -

Published: December 2019

Background: The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value.

Methods: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed.

Results: Mean ISQ value for all implants was 67.21±9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30).

Conclusions: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S0026-4970.19.04242-0DOI Listing

Publication Analysis

Top Keywords

implant
10
isq
9
primary stability
8
self-tapping dual
8
dual etched
8
etched implants
8
primary implant
8
implant stability
8
parameters implant
8
implant length
8

Similar Publications

Objective: This study aimed to determine if routine dual-stage nonunion repair (DSR) surgery lead to better outcomes than single-stage nonunion (SSR) repair surgery in fracture nonunions without evident clinical or laboratory signs of infection.

Methods: Design: Retrospective comparison study.

Setting: Level One Trauma Center affiliated with an academic teaching hospital.

View Article and Find Full Text PDF

Sinus membrane perforations are among the most commonly reported intraoperative complications encountered during maxillary sinus floor elevation procedures performed via the lateral window approach. Large perforations (> 10 mm) can pose a major clinical challenge, and often result in failed bone augmentation and poorer long-term implant survival. Owing to these challenges, even a highly skilled oral implant surgeon with advanced training in implantology faced with such perforations may abandon grafting procedures in favor of a reentry approach.

View Article and Find Full Text PDF

Purpose: The study aimed to compare the short-term outcomes (3.7±0.4yrs) of full-arch immediately loaded fixed maxillary prostheses supported by conventional and unilateral single zygomatic implants versus those supported by conventional and bilateral single zygomatic implants.

View Article and Find Full Text PDF

A prediction method and evaluation for assessing guide-supported dental implant accuracy.

Comput Methods Biomech Biomed Engin

February 2025

Zhejiang Weilian Technology Co., Ltd, Jiaxing, China.

Functional and esthetic results require accurate implant placement. We aimed to develop a predictive method for assessing dental implant accuracy, and to evaluate the cumulative system influence of surgical guides. A mathematical model was constructed to determine the influence of surface changes on a specific point, using Jacobian matrix expressions.

View Article and Find Full Text PDF

Patient-reported outcomes of zirconia dental implants: a systematic review and future directions.

J Patient Rep Outcomes

January 2025

Division of Oral Surgery and Orthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Graz, Austria.

Purpose: Zirconia dental implants show excellent biocompatibility and tissue integration, low affinity for plaque, and favorable biomechanical properties. However, these objective measures do not adequately replicate the patient's perception. This systematic review evaluated the evidence on patient-reported outcome (PROs) in zirconia dental implant treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!