Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The aims were to demonstrate pharmacokinetic (PK) similarity between DRL_RI, a proposed rituximab biosimilar, and two reference innovator products (Rituxan [RTX-US] and MabThera [RTX-EU]) and compare their pharmacodynamics (PD), efficacy, safety, and immunogenicity in rheumatoid arthritis (RA) patients with inadequate response to methotrexate (MTX)-based therapy and no prior biologic administration.
Methods: In this randomized, double-blind, parallel-group study, 276 patients with moderate-to-severe active RA were randomized to receive DRL_RI, RTX-US, or RTX-EU on days 1 and 15. The primary PK end points included area under the concentration-time curve from time 0 to 336 h after first infusion (AUC), AUC from day 1 through week 16 (AUC), and AUC from time 0 to time of last quantifiable concentration after the second dose (AUC). Secondary end points included other PK parameters, such as maximum concentration (C), time to C after each infusion, terminal half-life, systemic clearance, and volume of distribution after the second infusion; PD parameters and efficacy until week 24; safety and immunogenicity at week 24 and 52; and B cell recovery until week 52. AUC from time 0 to time of last quantifiable concentration after the first dose and over the entire course from day 1 through week 16 (AUC) was analyzed as an exploratory end point.
Results: The 91% confidence intervals (CIs) of the geometric mean ratios (GMRs) for the primary end point of AUC were within the bioequivalence limits of 80-125% for all comparisons: DRL_RI versus RTX-US 100.37% (92.30-109.14), DRL_RI versus RTX-EU 93.58% (85.98-101.85), and RTX-US versus RTX-EU 93.24% (85.62-101.54). PD outcomes (peripheral blood B-cell depletion and mean change in Disease Activity Score [28 joints]-C-reactive protein), efficacy, safety, and immunogenicity were also comparable between DRL_RI and the reference products.
Conclusion: DRL_RI, a proposed biosimilar, demonstrated three-way PK similarity with RTX-EU and RTX-US, the reference innovator products, with comparable efficacy, PD, safety, and immunogenicity.
Clinical Trials Registration Number: ClinicalTrials.gov identifier: NCT02296775.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7113224 | PMC |
http://dx.doi.org/10.1007/s40259-020-00406-1 | DOI Listing |