We investigated blood pressure (BP) and heart rate variability and baroreflex sensitivity (BRS) in white-coat, masked and sustained hypertension in untreated patients (n = 645). Normotension and white-coat, masked, and sustained hypertension were defined according to the clinic (cutoff 140/90 mmHg) and 24-h ambulatory (130/80 mmHg) BPs. The Finometer device recorded beat-to-beat finger BP and electrocardiograms in the supine and standing positions for the computation of frequency-domain power-spectral BP and heart rate variability indexes and BRS. In multivariate analysis, BP variability indexes in the supine position differed significantly (P < 0.0001) for both low-frequency (LF) and high-frequency (HF) components and the LF/HF ratio, with the lowest LF and HF power and highest LF/HF ratio in white-coat hypertension (n = 28), the highest LF and HF power and lowest LF/HF ratio in sustained hypertension (n = 198), and intermediate values in normotension (n = 189) and masked hypertension (n = 230). These differences diminished in the standing position, being significant (P < 0.0001) only for the LF component variability. The LF/HF ratio in BP in the supine position decreased with advancing age in normotension and sustained hypertension (P ≤ 0.03) but not white-coat or masked hypertension (P ≥ 0.12). For heart rate variability, a significant difference was observed only for the LF component in the supine position (P = 0.0005), which was lowest in white-coat hypertension. BRS in masked and sustained hypertension was significantly (P ≤ 0.0001) lower than that in normotension in both supine and standing positions and decreased with advancing age (P ≤ 0.0001). In conclusion, masked, but not white-coat, hypertension showed similar patterns of, but slightly less severe, changes in BP and heart rate variability and BRS to sustained hypertension.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41440-020-0413-5 | DOI Listing |
Sci Rep
December 2024
Departamento de Astronomía, Universidad de Chile, Casilla 36-D, Santiago, Chile.
Multiple physiological traits correlates with lifespan, being unclear both the causal connection among them and with the process of ageing. In this paper, we show that six traits (such as metabolic rate, mass, heart rate, etc) acting at the system level, are all related to lifespan thru the existence of an approximately constant number of respiration cycles in a lifespan ([Formula: see text]), therefore, we find that those relationships are not independently related to ageing. In addition, we study if the approximately constant [Formula: see text] is possibly linked with the end-of-lifespan somatic mutation burden, another number recently found to be approximately constant (Cagan, Nature 604:517-524, 2022).
View Article and Find Full Text PDFSci Rep
December 2024
Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, 3-25-8 Nishi-shimbashi, Minato-ku, Tokyo, 105-8461, Japan.
B-type natriuretic peptide (BNP) levels accurately reflect the degree of cardiac overload in heart failure. Considering cardiac morphology and intracardiac pressure, including the left ventricular end-systolic volume index (LVESVI) and left ventricular end-diastolic volume index (LVEDVI), is essential for cardiac overload assessment. These indexes influence plasma BNP levels, and high heart rate is likely associated with cardiac morphology.
View Article and Find Full Text PDFSci Rep
December 2024
Harman International, HarmanX Neurosense, 30001 Cabot Dr, Novi, MI, 48377, USA.
Cognitive load (CL) is one of the leading factors moderating states and performance among drivers. Heavily increased CL may contribute to the development of mental stress. Averaged heart rate (HR) and heart rate variability (HRV) indices are shown to reflect CL levels in different tasks.
View Article and Find Full Text PDFBAY 2413555 is a novel selective and reversible positive allosteric modulator of the type 2 muscarinic acetylcholine (M2) receptor, aimed at enhancing parasympathetic signaling and restoring cardiac autonomic balance for the treatment of heart failure (HF). This study tested the safety, tolerability and pharmacokinetics of this novel therapeutic option. REMOTE-HF was a multicenter, double-blind, randomized, placebo-controlled, phase Ib dose-titration study with two active arms.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Department of Cardiology, Angiology and Intensive Care Medicine, University Heart Center Lübeck, Lübeck, Germany.
Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.
Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!