Facile fabrication and high ambient stability are strongly desired for the practical application of temperautre sensor in real-time wearable healthcare. Herein, a fully printed flexible temperature sensor based on cross-linked poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) was developed. By introducing the crosslinker of (3-glycidyloxypropyl)trimethoxysilane (GOPS) and the fluorinated polymer passivation (CYTOP), significant enhancements in humidity stability and temperature sensitivity of PEDOT:PSS based film were achieved. The prepared sensor exhibited excellent stability in environmental humidity ranged from 30% RH to 80% RH, and high sensitivity of -0.77% °C for temperature sensing between 25 °C and 50 °C. Moreover, a wireless temperature sensing platform was obtained by integrating the printed sensor to a printed flexible hybrid circuit, which performed a stable real-time healthcare monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7016104PMC
http://dx.doi.org/10.1038/s41598-020-59432-2DOI Listing

Publication Analysis

Top Keywords

fully printed
8
temperature sensor
8
humidity stability
8
healthcare monitoring
8
printed flexible
8
temperature sensing
8