Predictive Value of In Vivo MR Spectroscopy With Semilocalization by Adiabatic Selective Refocusing in Differentiating Clear Cell Renal Cell Carcinoma From Other Subtypes.

AJR Am J Roentgenol

Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, 610 University Ave, 3-957, Toronto, ON M5G 2M9, Canada.

Published: April 2020

The purpose of this study is to evaluate the diagnostic value of in vivo MR spectroscopy (MRS) with semilocalization by adiabatic selective refocusing (semi-LASER MRS) in differentiating clear cell renal cell carcinoma (RCC) from the non-clear cell subtype. Sixteen patients with biopsy-proven RCC or masses highly suspicious for RCC were prospectively recruited to participate in the study. Single-voxel H spectra were acquired using a 3-T MRI system, with a semi-LASER sequence acquired for renal tumors in 14 patients and for healthy renal tissue (control tissue) in 12 patients. Offline processing of the MR spectra was performed. MRI and spectra analysis were performed independently by radiologists who were blinded to the reference histopathologic findings. Semi-LASER MRS was diagnostic for nine of 11 patients (82%) with histopathologically proven clear cell RCC, showing a strong lipid peak in seven patients and a weaker lipid resonance in two others, whereas control spectra showed weakly positive findings in only one patient. MRS findings were negative for lipid resonance in two of three patients (67%) with non-clear cell tumors and were weakly positive in another patient. Semi-LASER MRS had a high sensitivity and positive predictive value of 82% and 90%, respectively, in addition to a specificity of 67%, a negative predictive value of 50%, and overall accuracy of 79% for the detection of clear cell RCC. Lipid resonance was detected by MRS for four of six clear cell RCCs with no intravoxel fat on chemical-shift MRI. The preliminary results of the present study show that semi-LASER MRS is promising for the noninvasive discrimination of clear cell RCC from non-clear cell RCC on the basis of detection of lipid resonance and that it provides an incremental yield compared with chemical-shift MRI.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.19.22023DOI Listing

Publication Analysis

Top Keywords

clear cell
24
cell rcc
16
lipid resonance
16
non-clear cell
12
cell
11
vivo spectroscopy
8
spectroscopy semilocalization
8
semilocalization adiabatic
8
adiabatic selective
8
selective refocusing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!