AI Article Synopsis

  • Diabetes mellitus (DM) significantly alters corneal biomechanical properties, with a novel index developed to assess these changes based on dynamic corneal response parameters.
  • A study involving 81 DM patients and 75 healthy individuals demonstrated that corneal hysteresis and various dynamic response metrics were higher in DM patients, indicating distinct biomechanical differences.
  • The findings suggest that factors like disease duration and severity of diabetic eye conditions correlate with specific corneal biomechanical measurements, enhancing the understanding of diabetes's impact on ocular health.

Article Abstract

Purpose: Diabetes mellitus (DM) induces changes in corneal biomechanical properties. The influence of disease-specific factors was evaluated, and a novel DM index was created.

Methods: Eighty-one patients with DM and 75 healthy subjects were matched according to age, intraocular pressure, and central corneal thickness. Information on the disease was collected, and measurements with the Ocular Response Analyzer and the Corvis ST were taken. Results were compared between the groups, and the influence of disease-specific factors was evaluated. From dynamic corneal response parameters, a DM index was calculated.

Results: In DM, corneal hysteresis was higher than in healthy subjects (10.5 ± 1.9 vs. 9.7 ± 1.9 mm Hg, P = 0.008). In addition, dynamic corneal response parameters showed significant differences. Among others, highest concavity (HC) (17.212 ± 0.444 vs. 16.632 ± 0.794 ms, P < 0.001) and A2 time (21.85 ± 0.459 vs. 21.674 ± 0.447 ms, P = 0.017) as well as A1 (0.108 ± 0.008 vs. 0.104 ± 0.011 mm, P = 0.019) and A2 deflection amplitudes (0.127 ± 0.014 vs. 0.119 ± 0.014 mm, P < 0.001) were increased in DM. In DM type 1, HC deformation amplitude (1.14 ± 0.19 vs. 1.095 ± 0.114 mm, P = 0.035) was higher than in type 2. The time of deflection amplitude max correlated with the severity of retinopathy (R = 0.254, P= 0.023). In case of diabetic maculopathy, A1 velocity (0.155 ± 0.018 vs. 0.144 ± 0.019 ms, P = 0.043) and A2 time (22.052 ± 0.395 vs. 21.79 ± 0.46 ms, P = 0.04) were increased. Deformation amplitude max (R = 0.297, P = 0.024), HC time (R = 0.26, P = 0.049), HC deformation amplitude (R = 0.297, P = 0.024), and A2 deformation amplitude (R = 0.276, P = 0.036) were associated to disease duration. The DM index revealed a sensitivity of 0.773 and a specificity of 0.808 (area under the curve of receiver operating characteristic = 0.833).

Conclusions: In DM, changes in corneal biomechanics were correlated with disease-specific factors. The DM index achieved reliable sensitivity and specificity values.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000002275DOI Listing

Publication Analysis

Top Keywords

deformation amplitude
16
disease-specific factors
12
corneal biomechanics
8
diabetes mellitus
8
changes corneal
8
influence disease-specific
8
factors evaluated
8
healthy subjects
8
dynamic corneal
8
corneal response
8

Similar Publications

Short-term orthokeratology effects on corneal biomechanics with a focus on SPA1 and stress-strain index (SSI) parameters in pediatric myopia.

Arq Bras Oftalmol

January 2025

Department of Ophthalmology, Guangdong Eye Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences. No. 106 Zhongshan Er Road, Guangzhou 510080, China.

Purpose: Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in recent clinical investigations. This prospective study aimed to investigate corneal biomechanics changes induced by short-term overnight orthokeratology treatment, focusing on stiffness parameter at A1 and stress-strain index.

View Article and Find Full Text PDF

In living organisms, the natural motion caused by heartbeat, breathing, or muscle movements leads to the deformation of tissue caused by translation and stretching of the tissue structure. This effect results in the displacement or deformation of the plane of observation for intravital microscopy and causes motion-induced aberrations of the resulting image data. This, in turn, places severe limitations on the time during which specific events can be observed in intravital imaging experiments.

View Article and Find Full Text PDF

: The purpose of this study was to investigate dynamic responses of Lenke1B+ spines of adolescent scoliosis patients to different frequencies. : Modal analysis, harmonic response analysis and transient dynamics of a full spine model inverted by the finite element method using Abaqus. : The first-order axial resonance frequency of 4.

View Article and Find Full Text PDF

Objective: To observe and measure the morphological and temporal evolutionary features of the hypersynchronous (HYP) pattern in the mesial temporal seizure.

Methods: The HYP patterns during preictal and interictal states of 16 mesial temporal epileptic patients were analyzed. The wave components of the HYP transients were firstly observed and measured.

View Article and Find Full Text PDF

Functional and Structural Changes in the Inner Ear and Cochlear Hair Cell Loss Induced by Hypergravity.

Int J Mol Sci

January 2025

Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Inha University, Incheon 22332, Republic of Korea.

Gravitational changes have been shown to cause significant abnormalities in various body systems, including the cardiovascular, immune, vestibular, and musculoskeletal systems. While numerous studies have examined the response of the vestibular system to gravitational stimulation, research on functional changes in the peripheral inner ear remains limited. The inner ear comprises two closely related structures: the vestibule and cochlea.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!