The electrochemical flow cell containing track-etched microporous membrane electrodes was applied to a dual-electrode coulometric detector for microbore/capillary HPLC with a small injection volume and low eluent flow rate. The proposed flow cell with a 0.1-mm diameter inlet channel gave a detection volume of 0.08 nL per electrode, which was determined by the eluent flow through the electrode. For the dual-electrode detector, the calculated volume was 0.24 nL. The efficiency of electrooxidation of l-ascorbic acid increased as the flow rate decreased and was close to 100% when the flow rate was below 50 μL min, which is a common flow rate in microbore or capillary liquid chromatography. Catecholamines, such as noradrenaline, adrenaline, and dopamine, were detected by total conversion with two-electron oxidation in the potential range from 0.8 to 1.0 V vs. Ag/AgCl after separation with a microbore column. These peaks were accompanied by corresponding cathodic peaks derived from quasi-stable electrooxidation products of the catecholamines. The detection limits of noradrenaline, adrenaline, and dopamine were 0.1, 0.1, and 0.2 μM, respectively. The RSD values for five replicate measurements of 5.0 μM of these compounds were 0.9%, 0.7%, and 1.5%, respectively. Coulometric detection was also demonstrated by determination of catecholamines in pharmaceuticals.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2019.12.045DOI Listing

Publication Analysis

Top Keywords

flow rate
16
dual-electrode coulometric
8
coulometric detector
8
detector microbore/capillary
8
liquid chromatography
8
flow cell
8
eluent flow
8
noradrenaline adrenaline
8
adrenaline dopamine
8
flow
7

Similar Publications

The recovery of valuable materials from spent lithium-ion batteries (LIBs) has experienced increasing demand in recent years. Current recycling technologies are typically energy-intensive and are often plagued by high operation costs, low processing efficiency, and environmental pollution concerns. In this study, an efficient and environmentally friendly dielectrophoresis (DEP)-based approach is proposed to separate the main components of "black mass" mixtures from LIBs, specifically lithium iron phosphate (LFP) and graphite, based on their polarizability differences.

View Article and Find Full Text PDF

Background: To investigate the effect of Midnight-noon Ebb-flow combined with five-element music therapy in the continuous nursing of patients with chronic wounds.

Methods: From March 2022 to November 2023, we recruited 50 eligible chronic wound patients and randomly divided them into two groups according to a random number table: the experimental group (n = 25) and the control group (n = 25). The control group was treated with conventional nursing measures.

View Article and Find Full Text PDF

Somatic mutations in individual cells lead to genomic mosaicism, contributing to the intricate regulatory landscape of genetic disorders and cancers. To evaluate and refine the detection of somatic mosaicism across different technologies with personalized donor-specific assembly (DSA), we obtained tissue from the dorsolateral prefrontal cortex (DLPFC) of a post-mortem neurotypical 31-year-old individual. We sequenced bulk DLPFC tissue using Oxford Nanopore Technologies (∼60X), NovaSeq (∼30X), and linked-read sequencing (∼28X).

View Article and Find Full Text PDF

We present a case of an adult patient with a large symptomatic fusiform basilar artery aneurysm. This video demonstrates the ease of deploying the new Pipeline™ Vantage Flow Diverter compared to the Flex model in the same vessel. The Flex and Vantage have different deployment techniques-as using the Flex maneuvering technique on the Vantage may damage the braid.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the clinical efficacy and safety of silodosin in female patients with lower urinary tract symptoms (LUTSs), addressing the limited evidence supporting alpha-blocker use in this population.

Methods: A 12-week, single-arm, prospective, open-label study was conducted from May 2021 to January 2023. Female patients aged over 18 with an International Prostate Symptom Score (IPSS) ≥ 8 were enrolled and treated with silodosin (8 mg once daily).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!