A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Discrepancies between positron emission tomography/magnetic resonance imaging and positron emission tomography/computed tomography in a cohort of oncological patients. | LitMetric

Introduction: This study aims to evaluate discrepant findings between positron emission tomography/magnetic resonance imaging (PET/MRI) and positron emission tomography/computed tomography (PET/CT) in a cohort of oncological patients and to undertake a phantom study to assess the potential for extended PET acquisitions to lead to false-positive findings on PET/MRI.

Methods: Discrepant findings from a series of 106 patients undergoing same-day F-fluorodeoxyglucose (FDG)-PET/CT and PET/MRI were reviewed. Phantom studies explored the potential for PET acquisition time to contribute to discrepancy.

Results: There were 14 discrepant cases, 5 (35.7%) of which related to PET/MRI acquisitions that had been extended to 10 min. Three of these five cases proved to be falsely positive. Phantom studies showed greater contrast recovery and signal to noise ratio for 10-min PET/MRI acquisitions compared to 2-min acquisitions using PET/CT. There were no discrepancies when PET/CT showed disseminated disease (P = 0.036).

Conclusions: Extended PET/MRI acquisitions used to accommodate multiple MRI sequences may be associated with false-positive findings compared to PET/CT. PET/MRI is more likely to have incremental value when the prior probability for disseminated disease is low.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1754-9485.13000DOI Listing

Publication Analysis

Top Keywords

positron emission
16
pet/mri acquisitions
12
emission tomography/magnetic
8
tomography/magnetic resonance
8
resonance imaging
8
emission tomography/computed
8
tomography/computed tomography
8
cohort oncological
8
oncological patients
8
discrepant findings
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!