Direct Implantation of a Left Atrial Appendage Occluder During Cardiothoracic Surgery.

Ann Thorac Surg

Arrhythmia Unit, Cardiovascular Center, OLV Hospital, Aalst, Belgium; Department of Cardiovascular Surgery, OLV Hospital, Aalst, Belgium.

Published: September 2020

Surgical suture or exclusion of the left atrial appendage (LAA) is a commonly performed technique in patients undergoing cardiothoracic revascularization or valve repair, or both. However, incomplete surgical sealing of the LAA is not a rare phenomenon and strongly increases the risk for future cerebrovascular embolic events. We report the implantation of a Watchman LAA occluder (Boston Scientific, Natick, MA) during redo minimally invasive open heart surgery. This approach offers a new alternative for LAA occlusion in patients for whom a surgical procedure is scheduled.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2019.12.055DOI Listing

Publication Analysis

Top Keywords

left atrial
8
atrial appendage
8
direct implantation
4
implantation left
4
appendage occluder
4
occluder cardiothoracic
4
cardiothoracic surgery
4
surgery surgical
4
surgical suture
4
suture exclusion
4

Similar Publications

Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.

View Article and Find Full Text PDF

Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.

View Article and Find Full Text PDF

Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.

Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.

View Article and Find Full Text PDF

Objective: To explore the risk factors associated with postoperative atrial fibrillation (POAF) after off-pump coronary artery bypass grafting (OPCABG) and to construct a nomogram predictive model.

Methods: In this retrospective cohort study, clinical data of 193 patients who received OPCABG in Huai'an First People's Hospital Affiliated to Nanjing Medical University from June 2021 to November 2023 were retrospectively analyzed. Based on the established diagnosis of POAF, patients were divided into the POAF group (n=75) and the non-POAF group (n=118).

View Article and Find Full Text PDF

Background: Up to 50% of patients undergoing mitral transcatheter edge-to-edge repair (MTEER) have an indication for left atrial appendage occlusion (LAAO). However, prospective evaluation of this strategy is lacking.

Objectives: The aim of the study was to prospectively evaluate the outcomes of combined LAAO and MTEER.