A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inertial motion capture validation of 3D knee kinematics at various gait speed on the treadmill with a double-pose calibration. | LitMetric

Inertial motion capture validation of 3D knee kinematics at various gait speed on the treadmill with a double-pose calibration.

Gait Posture

Laboratoire de Recherche en Imagerie et Orthopédie (LIO), Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM), 900 St-Denis, Montréal, QC, H2X 0A9, Canada; École de Technologie Supérieure, Département du génie de la Production Automatisée, 1100 rue Notre-Dame Ouest, Montréal, QC, H2L 2W5, Canada.

Published: March 2020

Background: Inertial motion capture (IMC) is rapidly gaining in popularity to evaluate gait in clinical settings. Previous examinations of IMC knee kinematics were often limited to the sagittal plane and IMC calibration has not been thoroughly investigated.

Research Question: The objective was to validate IMC 3D knee kinematics calibrated with a double-pose during gait with reference to optical motion capture (OMC). The hypotheses are that IMC can estimate adequately knee kinematics and that both systems will detect similarly the changes with gait speed.

Methods: Twenty-four healthy participants walked on the treadmill at gait speed of 0.6, 0.8, 1.0 and 1.2 m/s. Knee kinematics were obtained simultaneously with two magnetic and inertial measurement units and passive markers fixed on the KneeKG system. OMC was calibrated with a functional anatomical approach and the IMC with a double-pose.

Results: Root mean square differences of the two systems yielded 3-6° for knee flexion, adduction and external rotation. Knee kinematics were more similar during the stance phase than the swing phase. Gait speed showed a significant progressive effect on the three knee angles that was similarly detected by the two systems.

Significance: IMC 3D knee kinematics can be obtained independently with a simple calibration and only two magnetic and inertial measurement units at an acceptable level of error especially during stance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2020.01.029DOI Listing

Publication Analysis

Top Keywords

knee kinematics
28
motion capture
12
gait speed
12
imc knee
12
knee
9
inertial motion
8
magnetic inertial
8
inertial measurement
8
measurement units
8
kinematics
7