The understanding of chemical-physical, morphological, and mechanical properties of polymer coatings is a crucial preliminary step for further biological evaluation of the processes occurring on the coatings' surface. Several studies have demonstrated how surface properties play a key role in the interactions between biomolecules (e.g., proteins, cells, extracellular matrix, and biological fluids) and titanium, such as chemical composition (investigated by means of XPS, TOF-SIMS, and ATR-FTIR), morphology (SEM-EDX), roughness (AFM), thickness (Ellipsometry), wettability (CA), solution-surface interactions (QCM-D), and mechanical features (hardness, elastic modulus, adhesion, and fatigue strength). In this review, we report an overview of the main analytical and mechanical methods commonly used to characterize polymer-based coatings deposited on titanium implants by electro-assisted techniques. A description of the relevance and shortcomings of each technique is described, in order to provide suitable information for the design and characterization of advanced coatings or for the optimization of the existing ones.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7040792PMC
http://dx.doi.org/10.3390/ma13030705DOI Listing

Publication Analysis

Top Keywords

titanium implants
8
surface characterization
4
characterization electro-assisted
4
electro-assisted titanium
4
implants multi-technique
4
multi-technique approach
4
approach understanding
4
understanding chemical-physical
4
chemical-physical morphological
4
morphological mechanical
4

Similar Publications

Recent Developments in Ventricular Assist Device Therapy.

Rev Cardiovasc Med

January 2025

Center for Preclinical Surgical & Interventional Research, The Texas Heart Institute, Houston, TX 77030, USA.

The evolution of left ventricular assist devices (LVADs) from large, pulsatile systems to compact, continuous-flow pumps has significantly improved implantation outcomes and patient mobility. Minimally invasive surgical techniques have emerged that offer reduced morbidity and enhanced recovery for LVAD recipients. Innovations in wireless power transfer technologies aim to mitigate driveline-related complications, enhancing patient safety and quality of life.

View Article and Find Full Text PDF

Background: Prosthetic joint infection is a serious complication that can arise after total joint replacement surgery. When bacteria colonise an orthopaedic implant, they form biofilms that protect them from their environment, making them difficult to remove. Treatment is further complicated by a global rise of antimicrobial resistance.

View Article and Find Full Text PDF

The periodontal ligament (PDL) is a connective tissue, and PDL cells have a potential to differentiate into cementoblasts, osteoblasts, and gingival fibroblasts. This study investigated whether transcription factor c-Myb could induce differentiation of PDL cells for periodontal regeneration. PDL cells were isolated from extracted teeth and cultured.

View Article and Find Full Text PDF

Objectives: The aim of this randomised controlled trial was to assess clinical, radiographic and patient reported outcomes of narrow versus standard diameter titanium zirconium (TiZr) implants supporting single crown restorations in posterior sites with limited bone width.

Materials And Methods: Participants requiring replacement of single missing posterior teeth with implant-supported crowns were randomly allocated into 2 treatment groups: narrow (3.3 mm) or standard (4.

View Article and Find Full Text PDF

Effects of thread design on soft and hard tissue healing around implants in lipopolysaccharide-induced peri-implantitis-like lesions in rat maxillae.

J Oral Biosci

January 2025

Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki 852-8588, Japan. Electronic address:

Objectives: This study investigated the effects of thread design on the soft and hard tissues around implants in rat maxillary peri-implantitis-like lesions.

Methods: Fourteen, 9-week-old, female Wistar rats were used in this study. Two types of grade IV titanium tissue-level implants with a standard V-shape and buttress threads were prepared (control and test implants, respectively).

View Article and Find Full Text PDF