A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Systematic analysis of button batteries', euro coins', and disk magnets' radiographic characteristics and the implications for the differential diagnosis of round radiopaque foreign bodies in the esophagus. | LitMetric

AI Article Synopsis

  • Button battery ingestion poses serious risks like esophageal perforation and requires careful diagnosis using chest X-rays.
  • The study assessed the X-ray imaging characteristics of various foreign bodies, including button batteries, euro coins, and disk magnets, examining them at different angles.
  • Results showed that button batteries of 20 mm or larger consistently demonstrated a double rim sign in X-rays, but this sign can also appear with other objects, like pot magnets.

Article Abstract

Objectives: Button battery (BB) ingestion can cause life-threatening complications such as esophageal perforation, and mediastinitis. Chest radiography is the method of choice to diagnose BB ingestion. Therefore, an adequate interpretation of X-ray imaging by physicians is mandatory. The study aimed to analyze relevant diagnostic aspects of BB X-ray imaging, and retrospective analysis of the imaging of radiopaque foreign bodies.

Methods: All commercially available BBs and different foreign bodies such as euro coins (EC) and disk magnets (DM) were listed according to their sizes and compositions. Furthermore, an X-ray analysis of a test set of BBs, ECs and DMs was performed at angles of 0°, 45°, and 90°. Retrospective assessment of radiological characteristics was performed for patients with a round and radiopaque foreign body in the esophagus RESULTS: Only BBs with a diameter of at least 20 mm had a reliable positive double rim sign at scan angles of 90°, and 45°. The step-off effect was visible in all BBs regardless of the diameter. DMs and ECs presented a homogeneous X-ray weakening at all investigated scan angles. In the retrospective analysis all five cases of BB ingestion showed a double rim sign, all fifteen cases of coin ingestion a homogeneous X-ray weakening. A corrugated margin was detected for 10 cent, 20 cent and 50 cent coins.

Conclusions: BBs with a diameter of at least 20 mm showed, depending on the battery model, a more or less pronounced double rim sign and step-off effect in conventional X-ray imaging. However the double rim sign can be simulated by for example a pot magnet.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijporl.2020.109917DOI Listing

Publication Analysis

Top Keywords

double rim
16
rim sign
16
radiopaque foreign
12
x-ray imaging
12
bbs diameter
12
round radiopaque
8
foreign bodies
8
retrospective analysis
8
diameter 20 mm
8
scan angles
8