Purpose: To evaluate the impact of cap thickness for small incision lenticule extraction (SMILE) on changes in corneal curvature and biomechanics.

Methods: One hundred eyes (50 patients) were enrolled in this prospective contralateral eye study. The difference in manifest refraction spherical equivalent (MRSE) in the same patient was less than 0.50 diopters. SMILE was performed with a randomized cap thickness of 110 µm in one eye and 140 µm in the other eye. MRSE, uncorrected distance visual acuity (UDVA), and corneal curvature and biomechanics were evaluated. The anterior and posterior surfaces of the corneal curvature (mean keratometry [Km] values 2, 4, and 6 mm from the pupil center) were measured by Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany) and changes in corneal biomechanics at 6 months postoperatively by Scheimpflug technology.

Results: There was no significant between-group difference in UDVA or MRSE postoperatively. Postoperative changes in Km at the anterior surface (ΔKm-ant) in the 4-mm zone were significantly higher in the 110-µm group than in the 140-µm group at 1 day and 1, 3, and 6 months postoperatively (P = .043, .045, .003, and .049, respectively); at 3 months, the ΔKm-ant in the 6-mm zone was higher in the 110-µm group (P = .035). The changes in second appla-nation time, deformation amplitude, and integrated radius were significantly less in the 110-µm group (P = .031, .049, and < .001, respectively).

Conclusions: A thicker corneal cap caused less change in anterior surface curvature after SMILE for moderate or low myopia, with no significant difference in UDVA and MRSE. [J Refract Surg. 2020;36(2):82-88.].

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20191216-01DOI Listing

Publication Analysis

Top Keywords

corneal curvature
16
cap thickness
12
110-µm group
12
corneal biomechanics
8
prospective contralateral
8
contralateral eye
8
eye study
8
changes corneal
8
µm eye
8
months postoperatively
8

Similar Publications

Background: The high myopia prevalence in young East Asian children necessitates early detection and prevention strategies. Axial length (AL), corneal radius of curvature (CR), and the AL to CR ratio (AL/CR) are potential myopia biomarkers. However, the influence of genetic, growth and development, and environmental factors on these metrics in Chinese preschool children remains unclear.

View Article and Find Full Text PDF

Purpose: Advancements in anterior segment imaging have significantly improved the precision of corneal diagnostics, aiding ocular conditions management. The study evaluated the agreement between two Scheimpflug devices-Pentacam and Remidio Visionix 650 (VX650)-in assessing corneal and anterior chamber parameters in patients with and without corneal abnormalities.

Materials And Methods: This prospective study at a tertiary eye care hospital measured pachymetry values (central corneal thickness, thinnest point), front corneal surface parameters (keratometry, curvature, astigmatism), back corneal surface parameters (elevation, curvature) and anterior chamber parameters (depth, volume, angle).

View Article and Find Full Text PDF

Purpose: Present a case of Mirvetuximab soravtansine (MIRV)-induced intraepithelial corneal deposits, review a proposed mechanism to explain the blurred vision our patient experienced, and explain clinical exams that may be used to support the diagnosis.

Observations: A 63-year-old female with metastatic ovarian cancer diagnosed with intraepithelial corneal deposits two weeks after her first MIRV infusion. Treatment with topical prednisolone acetate 1 % ophthalmic suspension and lubricating eye drops without interruption of her MIRV infusions resulted in complete resolution of blurry vision and corneal deposits.

View Article and Find Full Text PDF

Purpose: To investigate the changes in ocular biometry over time and their impact on intraocular lens (IOL) calculation in adult Korean patients with cataracts.

Methods: Inclusion criteria were patients who underwent two consecutive ocular biometric measurements spaced more than one year apart using the IOLMaster 700 between November 2019 and February 2024 at a tertiary hospital in Seoul, Korea. Longitudinal changes in ocular biometry were evaluated.

View Article and Find Full Text PDF

Purpose: The purpose is to measure the decentration after small incision lenticule extraction (SMILE) in eyes with high myopia and analyze its influence factors.

Methods: This retrospective study included 86 right eyes of 86 high myopia patients who underwent SMILE surgery in our hospital from August 2017 to December 2019. Patients were examined before the surgery and 3 months postoperatively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!