Dermoscopy and VISIA imager evaluations of non-insulated microneedle radiofrequency versus fractional CO laser treatments of striae distensae.

J Eur Acad Dermatol Venereol

Department of Dermatology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.

Published: August 2020

Backgrounds: Striae distensae (SD) has a known psychological impact due to the resulting cosmetic disfigurement. Many treatment modalities have been used over the years, but no standard interventions or evaluation methods have been proposed to date.

Objective: We compared the efficacy and safety of non-insulated microneedle radiofrequency (NIMRF) and fractional CO laser treatments of SD by objective measurements with dermoscopy and VISIA.

Methods: Fourteen females with severe SD were enrolled. These subjects had been treated three sessions of NIMRF and fractional CO laser for the right and left abdomen, respectively. Dermoscopy and VISIA imaging data, and photographs were collected at baseline and 2 months after the last treatment session. The global aesthetic improvement scale (GIAS) was scored by patients, and blinded investigators, pain score and satisfaction score were also documented. Any side effects were recorded.

Results: Ten patients completed the study. The GIAS from investigators and patients showed an overall improvement but without a significant difference (P = 0.18, P = 0.17, respectively). The decreased width measured by dermoscopy was between 5% and 32% (right side) and 6-31% (left side). There was no significant difference between both sides in either the per-protocol or intention to treat analyses (P = 0.149, P = 0.161, respectively). The mean pain score was 5.35 and 2.35 on the right side and left side, respectively, which was significant (P = 0.0016). Post-inflammatory hyperpigmentation (PIH) manifested in six patients on their left sides and four patients on their right sides. In most cases, this had resolved by the 3-month follow-up.

Conclusion: Non-insulated microneedle radiofrequency and fractional CO laser are both effective and safe treatment options for SD. PIH is a possible side effect but is more likely with fractional CO laser treatment. However, it clears up in most cases. Dermoscopy and VISIA are both convenient, digitalized methods of tracking subtle changes and monitoring the efficacy of SD treatments.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jdv.16266DOI Listing

Publication Analysis

Top Keywords

fractional laser
20
dermoscopy visia
12
non-insulated microneedle
12
microneedle radiofrequency
12
laser treatments
8
striae distensae
8
nimrf fractional
8
pain score
8
left side
8
side
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!