Comparison of QFT-Plus and QFT-GIT tests for diagnosis of infection in immunocompetent Korean subjects.

J Thorac Dis

Institute for Immunology and Immunological Diseases, Yonsei University College of Medicine, Seodaemun-gu, Seoul, Republic of Korea.

Published: December 2019

Background: QFT-Plus is a recently developed next-generation QuantiFERON-TB Gold In-Tube (QFT-GIT) test. Unlike the QFT-GIT test, it includes a TB2 antigen tube with peptides that may stimulate CD8+ T cells. This study evaluated the diagnostic performance of QFT-Plus and compared it with that of QFT-GIT.

Methods: QFT-Plus and QFT-GIT tests were performed in 33 patients with active tuberculosis (TB) and 57 healthy controls including subjects with latent TB infection (LTBI). Positivity and negativity of IFN-γ responses were compared between tests, and total concordance of the outcome was analyzed.

Results: Positive and negative outcomes of QFT-Plus and QFT-GIT tests showed substantial agreement (91.1%, kappa=0.8). The sensitivity and the specificity of QFT-Plus (93.9% sensitivity, 92.6% specificity) were similar with those of QFT-GIT (93.9% sensitivity, 100% specificity). Of eight discordant results, five (5.56%) and three (3.3%) were positive in QFT-GIT alone and QFT-plus alone, respectively. Reactivity in the TB2 tube contributes to the difference between QFT-GIT and QFT-Plus. Median IFN-γ production in TB2 (10.0 IU/mL in TB, 3.850 IU/mL in LTBI, P=0.001) is significantly higher in the TB group than the LTBI group. The QFT-Plus did not clearly discriminate between active TB and latent TB, although it showed significantly lower IFN-γ concentrations compared with the QFT-GIT in individuals with LTBI (3.850 7.205 IU/mL).

Conclusions: Similar accuracy of detecting infection was observed for QFT-Plus and QFT-GIT tests in immunocompetent patients and healthy controls, including those with LTBI. Improved efficacy for identifying infection was not found with the QFT-Plus, but further studies in a larger population may confirm the clinical significance of positive response in the TB2 tube of QFT-Plus.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6988008PMC
http://dx.doi.org/10.21037/jtd.2019.12.11DOI Listing

Publication Analysis

Top Keywords

qft-plus qft-git
16
qft-git tests
16
qft-plus
11
qft-git
10
qft-git test
8
healthy controls
8
controls including
8
939% sensitivity
8
qft-git qft-plus
8
tb2 tube
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!