Background: Modified electroconvulsive therapy (m-ECT) is utilized worldwide as an effective treatment for drug-resistant psychiatric disorders. However, during m-ECT, treatment of hypotension and hypertension in response to rapid hemodynamic changes is required. We used noninvasive continuous blood pressure monitoring system for continuous hemodynamic measurement during m-ECT.
Case Presentation: The patient was a 77-year-old man with depression complicated by coronary artery aneurysms (CAAs). We managed general anesthesia during m-ECT by using the ClearSight™ system (Edwards Lifesciences Corp, Irvine, CA, USA) for hemodynamic measurement. As a result, we performed a total of 10 m-ECTs. No rupture of CAAs or myocardial ischemia occurred and depressive symptoms improved.
Conclusion: We successfully managed the anesthesia in m-ECT for a depressed patient with CAAs without complications by using the ClearSight™ system, which was used for the effective management of circulatory fluctuations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6967071 | PMC |
http://dx.doi.org/10.1186/s40981-019-0298-y | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!