Optical coherence tomography (OCT) suffers from speckle noise due to the high spatial coherence of the utilized light source, leading to significant reductions in image quality and diagnostic capabilities. In the past, angular compounding techniques have been applied to suppress speckle noise. However, existing image registration methods usually guarantee pure angular compounding only within a relatively small field of view in the focal region, but produce spatial averaging in the other regions, resulting in resolution loss and image blur. This work develops an image registration model to correctly localize the real-space location of every pixel in an OCT image, for all depths. The registered images captured at different angles are fused into a speckle-reduced composite image. Digital focusing, based on the convolution of the complex OCT images and the conjugate of the point spread function (PSF), is studied to further enhance lateral resolution and contrast. As demonstrated by experiments, angular compounding with our improved image registration techniques and digital focusing, can effectively suppress speckle noise, enhance resolution and contrast, and reveal fine structures in ex-vivo imaged tissue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7002526PMC
http://dx.doi.org/10.1038/s41598-020-58454-0DOI Listing

Publication Analysis

Top Keywords

angular compounding
16
image registration
16
digital focusing
12
speckle noise
12
optical coherence
8
coherence tomography
8
image
8
suppress speckle
8
resolution contrast
8
angular
4

Similar Publications

Rheological investigations on frequency selective surface carbon composite microwave absorber.

Mater Horiz

October 2024

Stealth & Camouflage Division, Defence Material Store R & D Establishment, DRDO, Kanpur, UP 208013, India.

A high-performance stealth platform is one of the crucial requirements in defence technology that could practically be realized by building effective microwave frequency selective surface (FSS) absorbers. Herein, we report the design and manufacturing of an absorber by tuning the rheology of cell architecture. Initially, a fan-shaped cell (10.

View Article and Find Full Text PDF

Effect of Fluid Paraffin on the Formulation Properties of Pressure Sensitive Adhesive Formulations Containing Diclofenac Sodium.

AAPS PharmSciTech

October 2024

Department of Pharmaceutical Engineering and Drug Delivery Science, Graduate School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-Ku, Shizuoka-Shi, Shizuoka, 422-8526, Japan.

Understanding the relationship between the release characteristics of the active ingredient in the tape formulation and the pharmaceutical characteristics of the adhesive layer can optimize therapeutic efficacy and improve patient adherence. This study aimed to clarify the effect of liquid paraffine (LP)/styrene-isoprene-styrene (SIS) triblock copolymer ratio on pressure-sensitive adhesive (PSA) formulation properties, such as adhesive properties and drug release, with a certain amount of diclofenac sodium (DFS) and tackifier. The effects of changes in PSA composition in DFS-containing tape formulations on adhesive and drug release properties were evaluated.

View Article and Find Full Text PDF

Ultrasound imaging is a valuable clinical tool. It is commonly achieved using the delay and sum beamformer algorithm, which takes the signals received by an array of sensors and generates an image estimating the spatial distribution of the signal sources. This algorithm, while computationally efficient, has limited resolution and suffers from high side lobes.

View Article and Find Full Text PDF

Speckle degrades the quality of optical coherence tomography (OCT) images and impedes their visual interpretation. Current hardware methods for speckle suppression necessitate difficult hardware modifications. As a result, algorithmic approaches for speckle suppression generally lack validation or training with physically meaningful ground truth.

View Article and Find Full Text PDF

bistatic dual-aperture ultrasound imaging and elastography of the abdominal aorta.

Front Physiol

March 2024

Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.

In this paper we introduce multi-aperture ultrasound imaging and elastography of the abdominal aorta. Monitoring of the geometry and growth of abdominal aortic aneurysms (AAA) is paramount for risk stratification and intervention planning. However, such an assessment is limited by the lateral lumen-wall contrast and resolution of conventional ultrasound.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!