Objective: Benzodiazepines impair driving ability and psychomotor function. Eyelid parameters accurately reflect drowsiness; however, the effects of benzodiazepines on these measures have not been extensively studied. The aim of this study was to investigate the effect of benzodiazepines on eyelid parameters and evaluate their accuracy for detecting psychomotor impairment.

Methods: Eyelid parameters were recorded during a psychomotor vigilance task (PVT) and driving simulation over 2 days, baseline, and after 20-mg oral temazepam. The utility of eyelid parameters for detecting PVT lapses was evaluated using receiver operating characteristic curves, and cut-off levels indicating impairment (≥1 and ≥2 PVT lapses per min) were identified. The accuracy of these cut-off levels for detecting driving simulator crashes was then examined.

Results: PVT and driving simulator performance was significantly impaired following benzodiazepine administration (p < .05). Average eyelid closure duration (inter-event duration) was a reliable indicator of PVT lapses (area under the curve [AUC] of 0.87-0.90). The cut-off value of eyelid closure duration derived from PVT AUC was able to predict driving simulator crashes with moderately high sensitivity and specificity (76.23% and 75.00%).

Conclusions: Eyelid parameters were affected by benzodiazepines and accurately detected the psychomotor impairment. In particular, eyelid closure duration is a promising real-time indicator of benzodiazepine impairment.

Download full-text PDF

Source
http://dx.doi.org/10.1002/hup.2723DOI Listing

Publication Analysis

Top Keywords

eyelid parameters
20
pvt driving
8
pvt lapses
8
cut-off levels
8
driving simulator
8
eyelid
5
parameters
5
assessing validity
4
validity eyelid
4
parameters detect
4

Similar Publications

Purpose: to determine the effect of lower eyelid blepharoplasty (LEB) surgery on corneal biomechanical parameters before and four months after the procedure. Method: In this prospective longitudinal study, corneal biomechanical parameters measured by Corneal Visualization Scheimpflug Technology (Corvis ST, CVS, Oculus Optikgeräte GmbH, Germany) device were evaluated before and four months after LEB surgery.

Results: The study included 19 eyelids of the right eyes of 19 patients who underwent LEB, with a mean age of 49.

View Article and Find Full Text PDF

American alligators () are an important apex predator of semiaquatic habitats of the southern United States. Commercial alligator farming has grown in the last several decades, leading to a need to understand the health conditions that affect this species to ensure appropriate management and welfare. The aims of this study were 1) to establish and describe normative data including results of common ophthalmic diagnostic tests and conjunctival flora, 2) document ocular pathology in this population, and 3) assess the effect of topical rocuronium bromide and 10% phenylephrine for facilitating pharmacologic mydriasis.

View Article and Find Full Text PDF

Bilateral meibomian gland morphological alterations in unilateral herpes simplex keratitis based on artificial intelligence analysis.

Int J Ophthalmol

December 2024

National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China.

Aim: To explore whether unilateral herpes simplex keratitis (HSK) can cause morphological changes of bilateral meibomian glands (MGs) based on artificial intelligence (AI) analytical system.

Methods: In the retrospective study, 29 patients with unilateral HSK and 29 participants matched in terms of age and sex were included as control group. Meibographic images of the upper eyelid using Keratograph 5M and assessed ocular surface parameters including tear meniscus height and tear break-up time.

View Article and Find Full Text PDF

Kirigami Design Smart Contact Lens for Highly Sensitive Eyelid Pressure Measurement.

ACS Sens

December 2024

Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China.

Eyelid pressure is a crucial biomechanical parameter for ocular health and refractive status, yet measuring it poses challenges related to flexibility, sensitivity, and regional specificity. This study introduces a novel smart contact lens that incorporates kirigami designs and an iontronic capacitive sensing array to enhance flexibility and conformability. The unique structural composition of this device allows for precise and simultaneous monitoring of eyelid pressure in multiple regions with a high sensitivity and seamlessly fit across corneal curvatures.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of upper eyelid blepharoplasty with or without the removal of a strip of orbicularis oculi muscle on corneal topographic parameters, anterior segment parameters, intraocular pressure, and ocular biometry.

Method: This prospective study examined 428 eyes of 214 patients with dermatochalasis. Patients were divided into two groups randomly: those who underwent orbicularis oculi muscle excision (Group 1) during blepharoplasty and those who did not (Group 2).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!