The aims of this study were to evaluate the intra- and interobserver reproducibility of manual segmentation of bone sarcomas in magnetic resonance imaging (MRI) studies and to compare manual and semiautomatic segmentation methods. This retrospective study included twelve osteosarcoma and eight Ewing sarcoma MRI studies performed prior to any therapeutic intervention. All cases were histopathologically confirmed. Three radiologists used 3D-Slicer software to perform manual segmentation of bone sarcomas in a blinded and independent manner. One radiologist segmented manually and also performed semiautomatic segmentation with the GrowCut tool. Segmentation exercises were timed for comparison. The dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to evaluate similarity between the segmentation results and further statistical analyses were performed to compare DSC, HD, and volumetric results. Manual segmentation was reproducible with intraobserver DSC varying from 0.83 to 0.97 and HD from 3.37 to 28.73 mm. Interobserver DSC of manual segmentation showed variation from 0.73 to 0.97 and HD from 3.93 to 33.40 mm. Semiautomatic segmentation compared to manual segmentation resulted in DSCs of 0.71-0.96 and HDs of 5.38-31.54 mm. Semiautomatic segmentation required significantly less time compared to manual segmentation (P value ≤0.05). Among all situations compared, tumor volumetry did not show significant statistical differences (P value >0.05). We found excellent intra- and interobserver agreement for manual segmentation of osteosarcoma and Ewing sarcoma. There was high similarity between manual and semiautomatic segmentation, with a significant reduction of segmentation time using the semiautomatic method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6993358 | PMC |
http://dx.doi.org/10.1590/1414-431X20198962 | DOI Listing |
Heliyon
July 2024
D-Eye Srl, Padova, 35131, Italy.
Widespread screening is crucial for the early diagnosis and treatment of glaucoma, the leading cause of visual impairment and blindness. The development of portable technologies, such as smartphone-based ophthalmoscopes, able to image the optical nerve head, represents a resource for large-scale glaucoma screening. Indeed, they consist of an optical device attached to a common smartphone, making the overall device cheap and easy to use.
View Article and Find Full Text PDFNetwork
January 2025
Computer Science and Engineering, Vels Institute of Science, Technology & Advanced Studies (VISTAS), Chennai, India.
Skin cancer is one of the most prevalent and harmful forms of cancer, with early detection being crucial for successful treatment outcomes. However, current skin cancer detection methods often suffer from limitations such as reliance on manual inspection by clinicians, inconsistency in diagnostic accuracy, and a lack of personalized recommendations based on patient-specific data. In our work, we presented a Personalized Recommendation System to handle Skin Cancer at an early stage based on Hybrid Model (PRSSCHM).
View Article and Find Full Text PDFEur Radiol
January 2025
Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany.
Purpose: To investigate the test-retest repeatability of radiomic features in myocardial native T1 and T2 mapping.
Methods: In this prospective study, 50 healthy volunteers (29 women and 21 men, mean age 39.4 ± 13.
Radiol Artif Intell
January 2025
From the Department of Radiology (E.J.H., S.K., H.K., D. K., S.H.Y.) and Medical Research Collaborating Center (H.H.), Seoul National University Hospital, 101 Daehak- ro, Jongno-gu, Seoul 03080, Korea; Department of Radiology, Seoul National University College of Medicine (E.J.H., H.K., S.H.Y.), Seoul, Korea; Department of Radiology, Hanyang University Medical Center, Hanyang University College of Medicine (S-J.Y., Seoul, Korea).
Quantifying pleural effusion change on chest CT is important for evaluating disease severity and treatment response. The purpose of this study was to assess the accuracy of artificial intelligence (AI)-based volume quantification of pleural effusion change on CT images, using the volume of drained fluid as the reference standard. Seventy-nine participants (mean age, 65 ± [SD] 13 years; 47 male) undergoing thoracentesis were prospectively enrolled from October 2021 to September 2023.
View Article and Find Full Text PDFThe journal Lancet Psychiatry is launching a Commission for Youth Mental Health, in response to the widely reported finding in the media of a significant deterioration in the health of young people worldwide in recent years. The aim of this commission is to gain a better understanding of the factors that have led to this situation, and to offer care adapted to the needs of this segment of the population. In Lausanne, following the publication of a manual on psychotherapy for psychosis, a training course has been set up to promote this type of care, which is all too often denied to patients suffering from psychosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!