A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic accuracy of lamellar body count as a predictor of fetal lung maturity: A systematic review and meta-analysis. | LitMetric

Objective: This study aimed to synthesize evidence from published studies about the diagnostic accuracy of lamellar body count (LBC) as a predictor of fetal lung maturity.

Study Design: We searched Medline (via PubMed), EBSCO, Web of Science, Scopus and the Cochrane Library for relevant published studies assessing the accuracy of LBC as a predictor of fetal lung maturity. Studies were classified according to the counting essays, centrifugation protocols, and the reported optimum cut off values. Data of the true positive, true negative, false positive, and false negative were extracted and analyzed to calculate the overall sensitivity and specificity of the LBC.

Results: Thirty-one studies were included in the final analysis. Fourteen studies reported data for centrifuged amniotic fluid (AF) samples, 13 studies reported data for uncentrifuged samples, and four studies did not have enough information about whether centrifugation was done. LBC showed an area under the curve >80% in diagnosing lung immaturity with variable cut off values. Pooled analysis showed that LBC a 100% specificity to exclude respiratory distress syndrome (RDS) at a cut off value of 15,000 and 100% sensitivity to diagnose RDS at a cut off value of 55,000.

Conclusion: Cases with LBC < 15,000 are considered to have lung immaturity while cases with LBC > 45,000 in centrifuged AF samples or >55,000 in uncentrifuged AF samples are likely to have mature lungs. Cases with LBC ranging between these maturity and immaturity limits should be considered for further evaluation by other lung maturity tests.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6994392PMC
http://dx.doi.org/10.1016/j.eurox.2019.100059DOI Listing

Publication Analysis

Top Keywords

predictor fetal
12
fetal lung
12
lung maturity
12
diagnostic accuracy
8
accuracy lamellar
8
lamellar body
8
body count
8
published studies
8
lbc predictor
8
cut values
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!