Purpose: Due to the mechanical vulnerability of eyes that have undergone penetrating keratoplasty (PKP), it is clinically important to evaluate the possibility of corneal wound dehiscence by blunt impact. We have previously developed a simulation model resembling a human eye based on information obtained from cadaver eyes and applied three-dimensional finite element analysis (FEA) to determine the physical and mechanical response to an air gun impact at various velocities on the post-PKP eye.
Methods: Simulations in a human eye model were performed with a computer using a FEA program created by Nihon, ESI Group. The air gun pellet was set to impact the eye at three-different velocities in straight or 12° up-gaze positions with the addition of variation in keratoplasty suture strength of 30%, 50% and 100% of normal corneal strength.
Results: Furthermore to little damage in the case of 100% strength, in cases of lower strength in a straight-gaze position, wound rupture seemed to occur in the early phase (0.04-0.06 ms) of impact at low velocities, while regional break was observed at 0.14 ms after an impact at high velocity (75 m/s). In contrast, wound damage was observed in the lower quadrant of the suture zone and sclera in 12° up-gaze cases. Wound damage was observed 0.08 ms after an impact threatening corneoscleral laceration, and the involved area being larger in middle impact velocity (60 m/s) simulations than in lower impact velocity simulations, and larger damaged area was observed in high impact velocity cases and leading to corneoscleral laceration.
Conclusion: These results suggest that the eye is most susceptible to corneal damage around the suture area especially with a straight-gaze impact by an air gun, and that special precautionary measures should be considered in patients who undergo PKP. FEA using a human eyeball model might be a useful method to analyze and predict the mechanical features of eyes that undergo keratoplasty.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982457 | PMC |
http://dx.doi.org/10.2147/OPTH.S236825 | DOI Listing |
Nat Commun
December 2024
pi-Conjugated Polymers Unit, Okinawa Institute of Science and Technology, Kunigami-gun, Okinawa, Japan.
Irrespective of the specific see-through device, obtaining optimal transparency remains the primary goal. In this work, we introduce a general strategy to enhance the transparency of various see-through devices. We achieve this by structuring the colored functional materials into imperceptible three-dimensional mesh lines, addressing a common challenge in multi-layer structures where each layer causes a reduction in transparency due to their color or opacity.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
Department of Materials Science and Engineering, Chosun University, Gwangju 61452, Korea.
With the applications of in situ X-ray diffraction (XRD), electrical - measurement, and ambient pressure hard X-ray photoelectron spectroscopy (AP-HAXPES), the characteristics of the topotactic phase transition of LaCoO (LCO) thin films are examined. XRD measurements show clear evidence of structural phase transition (SPT) of the LCO thin films from the perovskite (PV) LaCoO to the brownmillerite (BM) LaCoO phases through the intermediate LaCoO phase at a temperature of 350 °C under high-vacuum conditions, ∼10 mbar. The reverse SPT from BM to PV phases is also found under ambient pressure (>100 mbar) of air near 100 °C.
View Article and Find Full Text PDFPsychol Res Behav Manag
December 2024
Department of Central Sterile Supply, Hainan General Hospital, Hainan Affiliated Hospital of Hainan Medical University, Haikou, 570311, People's Republic of China.
Objective: This study aimed to investigate whether noise exposure in hospital sterile supply centers exacerbated the psychological burden on staff, potentially mediated by concerns about physiological health.
Methods: Between July 5 and August 4, 2023, 308 staffs from central sterile supply departments in 30 hospitals in Hainan were chosen by convenient sampling method. They completed self-administered questionnaires to assess noise exposure status and used the Self-Reporting Inventory-90 to quantify the psychological state of staff across three dimensions: somatization, anxiety, and sleep and diet.
Sci Rep
December 2024
Institute of Life and Environmental Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, 305-8572, Ibaraki, Japan.
There is an urgent need for novel methods that can accurately predict intestinal absorption of orally administered drugs in humans. This study aimed to evaluate the potential of a novel gut microphysiological system (MPS), gut MPS/Fluid3D-X, to assess the intestinal absorption of drugs in humans. The gut MPS/Fluid3D-X model was constructed using a newly developed flow-controllable and dimethylpolysiloxane-free MPS device (Fluid3D-X).
View Article and Find Full Text PDFCureus
October 2024
Department of Plastic and Reconstructive Surgery and Burns Unit, Coimbra Local Health Unit, Coimbra, PRT.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!