A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The role of Micro-CT in imaging breast cancer specimens. | LitMetric

Purpose: The goal of breast cancer surgery is to remove all of the cancer with a minimum of normal tissue, but absence of full 3-dimensional information on the specimen makes this difficult to achieve.

Method: Micro-CT is a high resolution, X-ray, 3D imaging method, widely used in industry but rarely in medicine.

Results: We imaged and analyzed 173 partial mastectomies (129 ductal carcinomas, 14 lobular carcinomas, 28 DCIS). Imaging was simple and rapid. The size and shape of the cancers seen on Micro-CT closely matched the size and shape of the cancers seen at specimen dissection. Micro-CT images of multicentric/multifocal cancers revealed multiple non-contiguous masses. Micro-CT revealed cancer touching the specimen edge for 93% of the 114 cases judged margin positive by the pathologist, and 28 of the cases not seen as margin positive on pathological analysis; cancer occupied 1.55% of surface area when both the pathologist and Micro-CT suggested cancer at the edge, but only 0.45% of surface area for the "Micro-CT-Only-Positive Cases". Thus, Micro-CT detects cancers that touch a very small region of the specimen surface, which is likely to be missed on sectioning.

Conclusions: Micro-CT provides full 3D images of breast cancer specimens, allowing one to identify, in minutes rather than hours, while the patient is in OR, margin-positive cancers together with information on where the cancer touches the edge, in a fashion more accurate than possible from the histology slides alone.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10549-020-05547-zDOI Listing

Publication Analysis

Top Keywords

breast cancer
12
cancer
8
cancer specimens
8
size shape
8
shape cancers
8
margin positive
8
surface area
8
micro-ct
7
cancers
5
role micro-ct
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!