Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: We sought to compare intraoperative surgical instrumentation techniques with image-guidance versus robotic-guided procedures for posterior spinal fusion.
Methods: A retrospective review of institutional data collected from a single surgeon was used to compare surgical outcomes between O-arm neuronavigation and the Mazor X robotic-assistance system for placement of posterior spinal instrumentation in a consecutive series of patients. Univariate statistical significance testing compared time spent in the operating room, blood loss, screw accuracy, and wound healing.
Results: Between January 2017 and February 2019, 46 O-arm cases (mean age 59.6 years ± 13.7 years) and 39 Mazor X cases (mean age 59.5 years ± 12.4 years) were conducted. Cases were classified as degenerative, infectious, oncologic, and trauma with a mean of 4.57 and 5.43 levels operated on using O-arm neuronavigation and Mazor X, respectively. Mean operative times (P = 0.124), estimated blood loss (P = 0.212), wound revision rates (P = 0.560), and clinically acceptable instrumentation placement (P = 0.076) did not demonstrate significance between the 2 groups. However, screw placement was significantly more accurate and precise (P = 1 × 10) with robotic assistance when considering Gertzbein-Robbins A placement.
Conclusions: Although a trend toward greater accuracy was noticed with robotic technology when determining clinically acceptable screws, there was not a significant difference when compared with O-arm neuronavigation. However, robotic technology has a significant effect on both precision and accuracy in Gertzbein-Robbins A screw placement. Robotics does not have a clear advantage when discussing infection rates, intraoperative blood loss, or operative time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2020.01.175 | DOI Listing |