While a growing number of research studies have reported the inter-observer variability in computed tomographic (CT) measurements, there are very few interventional studies performed. We aimed to assess whether a peer benchmarking intervention tool may have an influence on reducing interobserver variability in CT measurements and identify possible barriers to the intervention. In this retrospective study, 13 board-certified radiologists repeatedly reviewed 10 CT image sets of lung lesions and hepatic metastases during 3 noncontiguous time periods (T1, T2, T3). Each preselected case contained normal anatomy cephalad and caudal to the lesion of interest. Lesion size measurement under RECISTS 1.1 guidelines, choice of CT slice, and time spent on measurement were captured. Prior to their final measurements, the participants were exposed to the intervention designed to reduce the number of measurements deviating from the median. Chi-square test was performed to identify radiologist-dependent factors associated with the variability. The percent of deviating measurements during T1 and T2 were 20.0% and 23.1%, respectively. There was no statistically significant change in the number of deviating measurements upon the presentation of the intervention despite the decrease in percent from 23.1% to 17.7%. The identified barriers to the intervention include clinical disagreements among radiologists. Specifically, the inter-observer variability was associated with the controversy over the choice of CT image slice (P = 0.045) and selection of start-point, axis, and end-point (P = 0.011). Clinical disagreements rather than random errors were barriers to reducing interobserver variability in CT measurement among experienced radiologists. Future interventions could aim to resolve the disagreement in an interactive approach.

Download full-text PDF

Source
http://dx.doi.org/10.1067/j.cpradiol.2020.01.008DOI Listing

Publication Analysis

Top Keywords

interobserver variability
12
variability computed
8
computed tomographic
8
experienced radiologists
8
inter-observer variability
8
reducing interobserver
8
barriers intervention
8
deviating measurements
8
clinical disagreements
8
intervention
6

Similar Publications

Objectives: To evaluate the performance of a 3D V-Net-based segmentation model of adrenal lesions in characterizing adrenal glands as normal or abnormal.

Methods: A total of 1086 CT image series with focal adrenal lesions were retrospectively collected, annotated, and used for the training of the adrenal lesion segmentation model. The dice similarity coefficient (DSC) of the test set was used to evaluate the segmentation performance.

View Article and Find Full Text PDF

Background: Multiple sclerosis (MS) is one of the most common disabling central nervous system diseases affecting young adults. Magnetic resonance imaging (MRI) is an essential tool for diagnosing and following up multiple sclerosis. Over the years, many MRI techniques have been developed to improve the sensitivity of MS disease detection.

View Article and Find Full Text PDF

Cranioventral pulmonary consolidation (CVPC) is a common lesion observed in the lungs of slaughtered pigs, often associated with Mycoplasma (M.) hyopneumoniae infection. There is a need to implement simple, fast, and valid CVPC scoring methods.

View Article and Find Full Text PDF

Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction.

BMC Med Imaging

January 2025

Department of Magnetic Resonance Imaging, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, 450052, China.

Background: Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.

View Article and Find Full Text PDF

Background And Purpose: A novel ring-gantry cone-beam computed tomography (CBCT) imaging system shows improved image quality compared to its conventional version, but its effect on autosegmentation is unknown. This study evaluates the impact of this high-performance CBCT on autosegmentation performance, inter-observer variability, contour correction times and delineation confidence, compared to the conventional CBCT.

Materials And Methods: Twenty prostate cancer patients were enrolled in this prospective clinical study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!