The NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component B has been progressively extended to span the -12 to 5 mT range, and as a trend, source performances improved with |B|. The progress of camera beam diagnostics and of the quality of the volume-produced H beam is also shown. The status, off-line results, and reliability of a first NIO1 cesium oven are discussed; other upgrades in preparation (cavity ring down spectrometer, the end calorimeter, and conceptual tests of the energy recovery system) are also listed.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5128658DOI Listing

Publication Analysis

Top Keywords

beam
4
beam installation
4
installation improvements
4
improvements nio1
4
nio1 ion
4
source
4
ion source
4
source nio1
4
nio1 negative
4
negative ion
4

Similar Publications

Background: Radiotherapy as a complement or an alternative to neurosurgery has a central role in the treatment of skull base grade I-II meningiomas. Radiotherapy techniques have improved considerably over the last two decades, becoming more effective and sparing more and more the healthy tissue surrounding the tumour. Currently, hypo-fractionated stereotactic radiotherapy (SRT) for small tumours and normo-fractionated intensity-modulated radiotherapy (IMRT) or proton-therapy (PT) for larger tumours are the most widely used techniques.

View Article and Find Full Text PDF

Enhancing furcation involvement classification on panoramic radiographs with vision transformers.

BMC Oral Health

January 2025

Department of Periodontics, Affiliated Hospital of Medical School, Nanjing Stomatological Hospital, Research Institute of Stomatology, Nanjing University, Nanjing, China.

Background: The severity of furcation involvement (FI) directly affected tooth prognosis and influenced treatment approaches. However, assessing, diagnosing, and treating molars with FI was complicated by anatomical and morphological variations. Cone-beam computed tomography (CBCT) enhanced diagnostic accuracy for detecting FI and measuring furcation defects.

View Article and Find Full Text PDF

Robot-assisted Endodontic Retreatment: A Case Report with Clinical Considerations.

J Endod

January 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China; Department of Cariology and Endodontics, School and Hospital of Stomatology, Wuhan University, Wuhan, China. Electronic address:

Introduction: Fiber posts present significant challenges for nonsurgical endodontic retreatment, as improper removal may result in iatrogenic root perforation or even root fracture. Recently, robotic technology has attracted considerable attention in dentistry and active dental robotic (ADR) systems can perform procedures based on preset instructions, minimizing reliance on the dentist's experience. This case report describes the application of an ADR system for fiber post removal through an existing zirconia crown.

View Article and Find Full Text PDF

The Strait of Sicily, a vital marine passage with diverse fauna, is seeing a steep rise in the planning of offshore wind farm projects. This study assesses the acoustic impact of these wind farms on local marine species. Underwater propagation was modeled for three proposed floating wind farms using JASCO's Marine Operations Noise Model (MONM), which integrates a parabolic equation method for frequencies from 10 to 800 Hz and a beam-tracing model for 1 to 25 kHz.

View Article and Find Full Text PDF

Background: Elemental analysis of teeth allows for exposure assessment during critical windows of development and is increasingly used to link early life exposures and health. The measurement of inorganic elements in teeth is challenging; laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is the most widely used technique.

Objective: Both synchrotron x-ray fluorescence (SXRF) and LA-ICP-MS have the capability to measure elemental distributions in teeth with each having distinct advantages and disadvantages.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!