A diagnostic complex for monitoring the position, propagation direction, and angular distribution dispersion of a particle beam planned for application in the Boron Neutron Capture Therapy facility is described in this paper. For the beam position and direction, the precision is, respectively, 0.1 mm and 1 mrad at 10 mA CW H- beam with energy of about 35 keV and a diameter of the order of 10 mm. The energy spread and angular divergence were measured within the accuracy of about 100 eV and 3 mrad, respectively. The acceptable precision of about 1 mm for the beam position is obtained at a relatively short exposure to 10 ms. To increase the radiation intensity of the beam, the addition of various gases was studied. The addition of gas decreases the beam width and increases the negative ions stripping.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5128565DOI Listing

Publication Analysis

Top Keywords

beam position
8
beam
7
optical diagnostics
4
diagnostics negative
4
negative ion
4
ion beam
4
beam transport
4
transport diagnostic
4
diagnostic complex
4
complex monitoring
4

Similar Publications

Objectives: To assess the effect of patient positioning and general anesthesia on the condylar position in orthognathic surgery.

Materials And Methods: This prospective study included patients undergoing orthognathic surgery between 2019 and 2020. Four weeks prior to surgery (T0) cone-beam computed tomography (CBCT) scans and intra-oral scans (IOS) were acquired in an upright position.

View Article and Find Full Text PDF

Pancreatic ductal adenocarcinoma (PDAC) is notably resistant to conventional chemotherapy and radiation treatment. However, clinical trials indicate that carbon ion radiotherapy (CIRT) with concurrent gemcitabine is effective for unresectable locally advanced PDAC. This study aimed to identify patient characteristics predictive of CIRT response.

View Article and Find Full Text PDF

An applied noise model for low-loss EELS maps.

Ultramicroscopy

January 2025

Nanopatterning-Nanoanalysis-Photonic Materials Group, Department of Physics, Paderborn University, Warburgerstr. 100, Paderborn, 33098, Germany. Electronic address:

Electron energy-loss spectroscopy (EELS) performed in a scanning transmission electron microscope (STEM) is susceptible to noise, just like every other measurement. EELS measurements are also affected by signal blurring, related to the energy distribution of the electron beam and the detector point spread function (PSF). Moreover, the signal blurring caused by the detector introduces correlation effects, which smooth the noise.

View Article and Find Full Text PDF

Recent investigations into radiation-induced side effects have focused on understanding the physiopathological consequences of irradiation on late-responding tissues like the spinal cord, which can lead to chronic progressive myelopathy. Proton therapy, an advanced radiation treatment, aims to minimize damage to healthy tissues through precise dose deposition. However, challenges remain, particularly regarding the variation in dose distribution, characterized by maximum deposition at the end of the proton range, known as the distal fall-off of a spread-out Bragg peak.

View Article and Find Full Text PDF

This study presents a patient with a PET-CT detected residual lacrimal sac tumor who was treated with intensity modulated proton therapy (IMPT) and concurrent chemotherapy. The patient a 49-year-old male diagnosed with squamous cell carcinoma of the left lacrimal sac had under-went endoscopic surgery. Postoperative PET-CT implied tumor residual in the left lacrimal sac.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!