Postoperative follow-up after cochlear implantation lacks a reliable screening method to detect cochlear implant receiver device migration. This study aims to validate a clinically applicable method to assess the position and migration of the cochlear implant receiver device. Validation study. Tertiary university medical center. To assess the cochlear implant receiver device location, round markers representing the external magnet were placed on both sides of the head of volunteers. Four independent clinicians took measurements of the distances between reference points on the head and the center of the marker. The reference points were: the lateral canthus (LC), tragus tip (TT), the mastoid angle (MA), and the mandibular angle (AM). The inter-clinician reliability was determined by calculating the intraclass correlation coefficient (ICC) and confidence interval (CI) with a two-way mixed model and both consistency and absolute agreement types for each distance. Eight volunteers were included resulting in 16 individual cases. The consistency type ICC's for each reference point were: LC 0.90 (CI = 0.80, 0.96), TT 0.83 (CI = 0.69, 0.93), MA 0.75 (CI = 0.56, 0.89), and AM 0.29 (CI = 0.05, 0.59). The absolute agreement ICC's were: LC 0.87 (CI = 0.73, 0.95), TT 0.83 (CI = 0.68, 0.93), MA 0.68 (CI = 0.42, 0.86), and AM 0.18 (CI = 0.01, 0.46). The inter-clinician reliability was good to excellent for the lateral canthus and tragus tip reference points. The cochlear receiver device location can be assessed reliably by measuring the distance between the LC, TT, and the external magnet. This method can be used to registrate implant receiver location after implantation and detect implant migration postoperatively.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6974530 | PMC |
http://dx.doi.org/10.3389/fsurg.2019.00078 | DOI Listing |
Rev Cardiovasc Med
January 2025
Department of Cardiovascular Medicine, Wonkwang University Medical School, 54536 Iksan, Republic of Korea.
Background: Right ventricular (RV) pacing exacerbates heart failure and increases cardiac mortality in patients with reduced ejection fraction (EF). However, its impact on left ventricular dysfunction in patients with preserved EF remains inconclusive. This study investigates the relationship between RV pacing, global longitudinal strain (GLS), and EF in patients with preserved EF.
View Article and Find Full Text PDFZhonghua Yi Xue Za Zhi
January 2025
Ophthalmology Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou310009, China.
To develop and validate a predictive model for assessing the risk of early postoperative high intraocular pressure (HIOP) following posterior chamber intraocular lens implantation. The clinical data of patients who underwent posterior chamber intraocular lens implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine between May 2023 and April 2024 were retrospectively reviewed. Patients were divided into a modeling group and a validation group with a 7∶3 ratio using computerized random allocation.
View Article and Find Full Text PDFBone Joint Res
January 2025
Department of Orthopaedics, Institute of Clinical Sciences, University of Gothenburg, Gothenburg, Sweden.
Aims: While cementless fixation offers potential advantages over cemented fixation, such as a shorter operating time, concerns linger over its higher cost and increased risk of periprosthetic fractures. If the risk of fracture can be forecasted, it would aid the shared decision-making process related to cementless stems. Our study aimed to develop and validate predictive models of periprosthetic femoral fracture (PPFF) necessitating revision and reoperation after elective total hip arthroplasty (THA).
View Article and Find Full Text PDFBiomol Biomed
January 2025
Department of Orthognathic Surgery and Maxillofacial Trauma, The Third Affiliated Hospital of Air Force Medical University, Xi'an, China.
Implant failure remains a significant challenge in oral implantology, necessitating a deeper understanding of its risk factors to improve treatment outcomes. This study aimed to enhance the clinical outcomes of oral implant restoration by investigating the factors contributing to implant failure in patients with partial dentition defects within two years of treatment. Additionally, the study sought to develop an early risk prediction model for implant failure.
View Article and Find Full Text PDFSpine (Phila Pa 1976)
January 2025
Department of Orthopaedics, Xijing Hospital, Air Force Medical University, Xi'an China.
Study Design/setting: A retrospective cohort study.
Objective: To compare long-term outcomes and complications of cervical disc replacement (CDR) and anterior cervical discectomy and fusion (ACDF) with cage-plate constructs (CPC) and stand-alone (SA) cages in treating degenerative cervical spondylosis.
Summary Of Background Data: ACDF is commonly used for cervical radiculopathy but may increase adjacent segment degeneration (ASD).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!