Introduction: Intra-aortic balloon pump (IABP) is a mechanical device that increases cardiac output by increasing diastolic blood flow to the coronary arteries and lowers the afterload of the left ventricle in systole. IABP is primarily used in acute heart failure, that includes patients that have to undergo coronary artery bypass grafting (CABG). Its usage, however, in cardiac surgery has been declining with ongoing controversy regarding its benefits. The aim of this study was to assess the use and indications and outcome of IABP related to CABG surgery.

Material And Methods: The study was retrospective and included 2177 patients that underwent CABG at Landspítali during 2001-2018. We compared those who received an IABP with controls, using uni- and multivariate analysis. Long term survival and complications (major adverse cardiovascular and cerebral events, MACCE) was estimated with Kaplan-Meier method.

Results: A total of 99 (4.5%) patients received an IABP. The incidence was highest in 2006 (8.9%) and lowest in 2001 (1.7%), but the incidence did not change during the study period (p=0.90). Most patients received the pump before (58.6%) or during (34.3%) CABG, but only 6.1% after surgery. Complication rate was 14.1%, with bleeding from the insertion site in the groin being the most common complication. Thirty day mortality was higher in the IABP group compared with controls (22.2% vs 1.3%, p<0.001) and both 5-year survival (56.4% vs 91.5%, 95% CI: 0.47-0.67) and 5-year MACCE-free survival (46.9% vs 83.0%, 95% CI: 0.38-0.58) were inferior.

Conclusions: Less than 5% of patients received IABP in relation to CABG in Iceland and the rate hasn't changed much for the last 18 years. Both the complication rate and 30-day mortality was higher in patients in IABP group and both the long term and MACCE-free survival was much worse, probably mostly related to worse overall clinical condition of the patient that received IABP.

Download full-text PDF

Source
http://dx.doi.org/10.17992/lbl.2020.02.372DOI Listing

Publication Analysis

Top Keywords

balloon pump
8
coronary artery
8
artery bypass
8
received iabp
8
patients received
8
iabp
6
[the intra
4
intra aortic
4
aortic balloon
4
pump coronary
4

Similar Publications

Intra-Aortic Balloon Pump: Down But Not Out.

Catheter Cardiovasc Interv

January 2025

Carl and Edyth Lindner Research Center, Christ Hospital, Cincinnati, Ohio, USA.

View Article and Find Full Text PDF

Background: The use of mechanical circulatory support devices for high-risk percutaneous coronary intervention (PCI) has increased over the past decade despite limited data of benefit. We sought to examine the association between intravascular microaxial left ventricular assist device (LVAD) versus intra-aortic balloon pump use in patients without cardiogenic shock (CS) undergoing PCI.

Methods And Results: This retrospective study analyzed claims data from a large, insured population who underwent PCI without CS from April 1, 2016 to July 31, 2022.

View Article and Find Full Text PDF

Biventricular Dysfunction Due to Chronic Mitral Valve Regurgitation Caused by Aberrant Mitral Arcade.

Ann Thorac Surg Short Rep

December 2024

Division of Cardiac Surgery, Department of Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania.

A 53-year-old male individual with chronic severe mitral regurgitation presented with biventricular dysfunction, pulmonary hypertension, and atrial fibrillation. Echocardiography demonstrated a posterior leaflet prolapse with malcoaptation. Mitral valve repair and Maze procedure were performed, revealing absent chordae and direct connection from the anterolateral papillary muscle to the posterior leaflet, consistent with partial mitral arcade.

View Article and Find Full Text PDF

Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.

View Article and Find Full Text PDF

Objective: The objective was to evaluate the relationship between carotid stenting and off-pump coronary artery grafting (CAS-OPCABG) and OPCABG only in patients with asymptomatic severe carotid stenosis.

Methods: This study retrospectively included 669 patients with asymptomatic severe carotid artery stenosis who underwent OPCABG at multiple centers. After propensity score matching for baseline characteristics, the study compared two groups of patients with clinical data, early and midterm death, stroke, and myocardial infarction (MI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!