Musculoskeletal models enable non-invasive estimation of knee contact forces (KCFs) during functional movements. However, the redundant nature of the musculoskeletal system and uncertainty in model parameters necessitates that model predictions are critically evaluated. This study compared KCF and muscle activation patterns predicted using a scaled generic model and OpenSim static optimization tool against in vivo measurements from six patients in the CAMS-knee datasets during level walking and squatting. Generally, the total KCFs were under-predicted (RMS: 47.55%BW, R: 0.92) throughout the gait cycle, but substiantially over-predicted (RMS: 105.7%BW, R: 0.81) during squatting. To understand the underlying etiology of the errors, muscle activations were compared to electromyography (EMG) signals, and showed good agreement during level walking. For squatting, however, the muscle activations showed large descrepancies especially for the biceps femoris long head. Errors in the predicted KCF and muscle activation patterns were greatest during deep squat. Hence suggesting that the errors mainly originate from muscle represented at the hip and an associated muscle co-contraction at the knee. Furthermore, there were substaintial differences in the ranking of subjects and activities based on peak KCFs in the simulations versus measurements. Thus, future simulation study designs must account for subject-specific uncertainties in musculoskeletal predictions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7089909PMC
http://dx.doi.org/10.1007/s10439-020-02465-5DOI Listing

Publication Analysis

Top Keywords

cams-knee datasets
8
kcf muscle
8
muscle activation
8
activation patterns
8
level walking
8
walking squatting
8
muscle activations
8
muscle
6
capacity generic
4
musculoskeletal
4

Similar Publications

As a solution to restore knee function and reduce pain, the demand for Total Knee Arthroplasty (TKA) has dramatically increased in recent decades. The high rates of dissatisfaction and revision makes it crucially important to understand the relationships between surgical factors and post-surgery knee performance. Tibial implant alignment in the sagittal plane (i.

View Article and Find Full Text PDF

Implant malalignment has been reported to be a primary reason for revision total knee arthroplasty (TKA). In addition, altered muscle coordination patterns are commonly observed in TKA patients, which is thought to alter knee contact loads. A comprehensive understanding of the influence of surgical implantation and muscle recruitment strategies on joint contact mechanics is crucial to improve surgical techniques, increase implant longevity, and inform rehabilitation protocols.

View Article and Find Full Text PDF

Knowledge of both tibio-femoral kinematics and kinetics is necessary for fully understanding knee joint biomechanics, guiding implant design and testing, and driving and validating computational models. In 2017, the CAMS-Knee datasets were presented, containing synchronized in vivo implant kinematics measured using a moving fluoroscope and tibio-femoral contact loads measured using instrumented implants from six subjects. However, to date, no representative summary of kinematics and kinetics obtained from measurements at the joint level of the same cohort of subjects exists.

View Article and Find Full Text PDF

The article The Capacity of Generic Musculoskeletal Simulations to Predict Knee Joint Loading Using the CAMS-Knee Datasets, written by Zohreh Imani Nejad et al., was originally published electronically on the publisher's internet portal on January 30, 2020 without open access. With the author(s)' decision to opt for Open Choice the copyright of the article changed on February 18, 2020 to © The Author(s) 2020 and the article is forthwith distributed under a Creative Commons Attribution 4.

View Article and Find Full Text PDF

Musculoskeletal models enable non-invasive estimation of knee contact forces (KCFs) during functional movements. However, the redundant nature of the musculoskeletal system and uncertainty in model parameters necessitates that model predictions are critically evaluated. This study compared KCF and muscle activation patterns predicted using a scaled generic model and OpenSim static optimization tool against in vivo measurements from six patients in the CAMS-knee datasets during level walking and squatting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!