Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Various adjunctive techniques for neurointerventional procedures require a large-bore sheath introducer, but there is concern that this could result in more puncture site hemorrhagic complications despite using a vascular closure device. The purpose of this study was to assess the relationship between use of large-bore sheath introducer and post-procedural complications. Between January 2016 and April 2018, 126 neurointerventional procedures were performed in our hospital using 8 or 9 Fr sheath introducer in size and the Angio-Seal STS PLUS (St. Jude Medical, Minnetonka, USA). Hemorrhagic complications were defined as obvious swelling or bleeding at the puncture site or as extravascular bleeding detected by ultrasonography or contrast-enhanced computed tomography. The procedures were divided into a group with post-puncture bleeding (group B, n = 21) and a group without bleeding (group N, n = 105). Risk factors were compared between the groups according to the incidence of post-puncture bleeding. In addition, we assessed the outcome and approach to hemostasis in the procedures with bleeding. In result, hemorrhagic complications occurred in 21 procedures (17%), and pseudoaneurysm was detected in 4 procedures (3.2%). In 20 of group B (16%), manual compression was performed for an average of 36.4 min. One patient (0.79%) required surgical angioplasty. Risk factors for bleeding were not significantly different between the two groups. None of the patients with bleeding showed a decrease on the modified Rankin Scale. In conclusion, use of a large-bore sheath introducer may increase the incidence of post-puncture bleeding, but the outcome of this complication is acceptable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jocn.2020.01.065 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!