Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of this study was to explore the efficacy, repeatability, and efficiency of a new intraoperative contactless device (INTEGRA Optomed, Chorzów, Poland) for determining the axis for toric intraocular lens implantation and then to compare this with that determined using a manual method.This study was conducted at the Ophthalmological Center for Children and Adults Optomed, Chorzów, Poland.This nonrandomized, retrospective, observational study included 20 eyes of 12 patients (5 males and 7 females) who had toric intraocular lens implanted. A video recording of each surgery using the INTEGRA system was made showing the analysis. The surgeon and one of the researchers then independently assessed the location of the implant axes determined with both digital and manual slit-lamp methods, and compared them.The implantation axes suggested for both the manual and INTEGRA methods were similar. The median axis disparities were 0.0 degree and 0.5 degree, and standard deviations were 0.61 and 0.81 for researcher 1 and 2, respectively. The dominant value was 0.0 in both groups. The INTEGRA axis designation was not statistically different from the manual method (level of significance: α < 0.01).The INTEGRA system is a digital ink-free device for image tracking scleral vessels. It was helpful for determining the implantation axis in a precise and repeatable manner, and measurements were comparable with a manual technique.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7004766 | PMC |
http://dx.doi.org/10.1097/MD.0000000000018582 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!