A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Computational approach and electrochemical measurements for protein detection with MIP-based sensor. | LitMetric

Rapid and accurate detection of proteins in biological fluids is increasingly required in the biomedical environment. Actually, it is performed with conventional techniques, which are generally run by robotized platforms at centralized laboratories. In this work, molecular dynamics calculations and an experimental procedure were conducted to set up electrochemical sensors based on polypyrrol (PPy) molecular imprinted polymers (MIP) for proteins detection. Here, prostate-specific antigen (PSA) was selected as a template model. Computational calculations indicate that for any PPy conformation and any amino-acid location in the protein, PSA molecules remain strongly inserted in the PPy polymer without biological alterations. One from possible orientations, appeared to be most probable as it presents the lowest absorption energy (-363 kcal mol) and largest contact area (4034.1 Å). The device was then elaborated by in situ electropolymerization of PPy films. MIP's thickness and extraction duration were optimized by chronoamperometry. Square wave voltammetry technique was investigated for PSA detection in standard solution in the concentration range of 3x10 ng.ml- 300 ng ml. According to the Hill equation, the equilibrium dissociation constant Kbetween PSA and its imprint was estimated at K = (1.02 ± 0.54) × 10 M, confirming the strong binding between the designed MIP and the protein as predicted by the computational study. PSA concentration values directly measured in 35 human serum samples were found closely correlated to those measured by the ELISA technique. The promising fast and low-cost sensor might be used successfully for proteins detection at low concentrations with high selectivity and reproducibility.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2019.111978DOI Listing

Publication Analysis

Top Keywords

proteins detection
8
detection
5
psa
5
computational approach
4
approach electrochemical
4
electrochemical measurements
4
measurements protein
4
protein detection
4
detection mip-based
4
mip-based sensor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!