The aim of this study was to compare the values of six methods in measuring the involvement of posterior malleolus and to demonstrate the reliability and reproducibility of each method. Three independent orthopaedic surgeons, retrospectively, measured 106 cases. The difference between the six methods was analyzed using Bonferroni-corrected paired -tests after one-way ANOVA. The agreement between the six methods was analyzed using Bland-Altman analysis. The intraclass correlation coefficient (ICC) was used to assess intraobserver reproducibility and interobserver reliability. Significant differences were observed between values of any two of the six measurement methods ( < 0.0033), except between any two of the plane radiograph linear, axial CT linear, sagittal CT linear, and 3D CT linear. The Bland-Altman plots demonstrated poor agreement between values of any two of the six methods. The lowest intraobserver reproducibility was 0.46 (moderate) for resident surgeon using plain radiographs. The intraobserver reproducibility for three surgeons using two-dimensional (2D) and 3D images was almost perfect (ICC, 0.82-0.96). The lowest interobserver reliability was 0.41 (moderate) between chief and attending surgeon using plain radiographs, and it improved to almost perfect (ICC, 0.81-0.95) with the use of 3D CT images. The standard error of measurement showed almost the same results as ICC values. The existing operative indications which were determined based on plain radiography are neither reliable nor suitable for other measurement methods. Both 3D linear and 3D surface measurement methods are reliable and reproducible in measuring posterior fragment involvement, and experience is not so crucial. Operative indications for posterior malleolar fractures need to be redefined based on the 3D measurement method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6970486PMC
http://dx.doi.org/10.1155/2020/6745626DOI Listing

Publication Analysis

Top Keywords

intraobserver reproducibility
12
measurement methods
12
involvement posterior
8
posterior malleolus
8
methods
8
values methods
8
methods analyzed
8
interobserver reliability
8
surgeon plain
8
plain radiographs
8

Similar Publications

Goal: Current methodologies for assessing cerebral compliance using pressure sensor technologies are prone to errors and issues with inter- and intra-observer consistency. RAP, a metric for measuring intracranial compensatory reserve (and therefore compliance), holds promise. It is derived using the moving correlation between intracranial pressure (ICP) and the pulse amplitude of ICP (AMP).

View Article and Find Full Text PDF

: The aim of this study is to assess the inter- and intra-observer reproducibility of the identification of direct and indirect ultrasonographic features of adenomyosis as defined by the revised Morphological Uterus Sonographic Assessment (MUSA) consensus (2022). : A cohort of 74 women, aged 18 to 45, were recruited from the recurrent miscarriage and general gynaecology clinic at a university-based fertility centre. All the participants underwent 2D and 3D transvaginal Ultrasound scan (TVS) examination in the late follicular and early luteal phase.

View Article and Find Full Text PDF

Purpose: Currently, no gold standard exists for 3D analysis of virtually planned surgery accuracy postoperatively. The aim of this study was to present a new, validated and standardised methodology for 3D postoperative assessment of surgical accuracy in patients undergoing 3D virtually planned and guided corrective osteotomies.

Methods: All patients who underwent 3D planned corrective osteotomy in 2021-2022 at our center with a postoperative CT were included.

View Article and Find Full Text PDF

We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included.

View Article and Find Full Text PDF

Background: The Oxford Shoulder Score (OSS) is a well-established and extensively utilized shoulder score translated into Western and Asian languages for use in respective countries. Our study aimed to translate, cross-culturally adapt, and psychometrically validate the OSS in the Tamil language community.

Methods: The translation and cross-cultural adaptation were conducted according to previously established standards.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!