A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of Tooth Preparation Design and Scan Angulations on the Accuracy of Two Intraoral Digital Scanners: An in Vitro Study Based on 3-Dimensional Comparisons. | LitMetric

Purpose: To evaluate the accuracy of two intraoral scanners (IOS) in terms of different preparation designs and scan angulation limitation due to the presence of adjacent teeth.

Materials And Methods: Eight different complete coverage (CC) and partial coverage (PC) tooth preparations were scanned by two IOS, the 3Shape TRIOS (TRI) and the 3M True Definition (TRU). All teeth preparations were scanned in the presence and absence of adjacent teeth. Four groups were established for each IOS; Group 1: PC preparations with adjacent teeth. Group 2: CC preparations with adjacent teeth. Group 3: PC preparations without adjacent teeth. Group 4: CC preparations without adjacent teeth. 3D analysis was performed to examine average absolute discrepancy (AAD) and maximum absolute discrepancy (MAD). A Two-way ANOVA was performed followed by a post-hoc Tukey's test HSD to evaluate the effect of adjacent teeth, preparation design, and the type of IOS used.

Results: For TRI, AAD for groups 1, 2, 3, and 4 were 20 ± 1.8 µm, 19.6 ± 2.4 µm, 15.5 ± 2.7 µm, and 12.9 ± 1.4 µm, respectively, whereas MAD for groups 1, 2, 3, and 4 were 109.7 ± 13.5 µm, 93.2 ± 28.9 µm, 85.6 ± 16.1 µm, and 66 ± 20.1 µm, respectively. For TRU IOS, AAD for groups 1, 2, 3, and 4 were 22.0 ± 3.6 µm, 17.9 ± 2 µm, 20 ± 5.9 µm, and 14.9 ± 1.7 µm, respectively, whereas the MAD for groups 1, 2, 3, and 4 were 151.4 ± 38.4 µm, 92.2 ± 17. µm, 92.6 ± 23.6 µm, and 71.4 ± 11.9 µm, respectively. Two-way ANOVA showed statistically significant differences between the AAD and MAD of TRI and TRU (p < 0.001). There were also statistically significant differences for presence or absence of adjacent teeth (p < 0.001), and preparation design (p < 0.001).

Conclusions: PC preparation scans revealed lower accuracy than CC. The presence of adjacent teeth decreased the accuracy of both IOS. TRI gave higher accuracy than TRU for PC, but both IOS showed comparable accuracy for CC groups.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13148DOI Listing

Publication Analysis

Top Keywords

adjacent teeth
32
group preparations
16
preparations adjacent
16
µm
16
preparation design
12
teeth group
12
adjacent
9
teeth
9
accuracy intraoral
8
presence adjacent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!