Background: Previous outcome studies in open tibial fractures have commonly assessed young patients and there is a paucity of data regarding outcomes in the elderly. The aim of this study is to assess functional outcomes for patients over 75 years with Gustilo-Anderson Grade III open tibial fractures, including mobility and residential status.

Methods: Outcomes for all patients over 75 years admitted with grade III open tibial fractures to a UK level 1 trauma centre during a 5-year period (January 2010-May 2015) were analysed. Long-term follow up of surviving patients (median 44 months post injury) was undertaken in February 2016.

Results: Twenty-nine patients (24 female, 5 male - median 85 years) were included. Prior to injury 48% (n = 14) patients were independently mobile and 45% (n = 13) were living at home without care. Two-thirds of injuries were low energy; all patients sustained a grade III open tibial fracture. The 12-month mortality rate was 28% (n = 8) and mortality at long-term follow-up 48% (n = 14). From pre-injury to long-term 8% (n = 1) patients did not change mobility status, 75% (n = 9) reduced by one grade (e.g. independent to walking aid) and 16% (n = 2) by two grades. Fifty eight percent (n = 7) of patients retained residential status, 17% (n = 2) reduced by one grade and 25% (n = 3) by two grades.

Conclusion: Grade III open tibial fractures are a significant injury in the elderly associated with poor outcomes with respect to return to mobility and pre-injury residential status. Our results suggest that a greater emphasis on intensive rehabilitation should be considered in this patient group.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6978180PMC
http://dx.doi.org/10.1016/j.jcot.2019.06.005DOI Listing

Publication Analysis

Top Keywords

tibial fractures
20
open tibial
20
grade iii
16
iii open
16
outcomes patients
12
patients years
12
patients
10
functional outcomes
8
48% n = 14
8
reduced grade
8

Similar Publications

The Impact of Fibular Fixation Method on Pilon Fracture Healing.

J Clin Med

January 2025

OhioHealth Orthopedic Trauma and Reconstructive Surgeons, Grant Medical Center, Columbus, OH 43215, USA.

Pilon fractures are associated with high-energy injuries, and there is presently much debate as to optimal fixation strategies and timing of intervention. There is little evidence comparing the type of fibular fixation during pilon fracture fixation. The purpose of this study was to compare fibular fixation methods in complex pilon injuries as it relates to pilon union rates and development of post-traumatic arthritis.

View Article and Find Full Text PDF

Proximal tibiofibular joint detachment (PTFJD) is a fibular untethering procedure during lateral closing-wedge high tibial osteotomy (LCWHTO) for varus knee osteoarthritis. However, the PTFJD procedure is technically demanding, and confirmation of clear joint separation is not straightforward. The aim of this study was to compare the degree of completion and safety of PTFJD versus tibial-sided osteotomy (TSO); this latter procedure is our novel technique for fibular untethering during LCWHTO.

View Article and Find Full Text PDF

The Effect of Local Melatonin Application on Bone Fracture Healing in Rat Tibias.

Medicina (Kaunas)

January 2025

Department of Peridontology, Faculty of Dentistry, Firat University, Elazig 23119, Türkiye.

This study aimed to histologically evaluate the effects of local melatonin application at different doses on bone fracture healing. Thirty rats were divided into three groups, with ten rats in each group. In the control group ( = 10), a fracture line was created in the tibial bones, and fracture osteosynthesis was performed without any additional procedure.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

Purpose: To investigate the factors that prolonged the operative duration (OD) in patients who underwent single-stage locked intramedullary nailing of their multiple concurrent long-bone fractures (LBFs) using Surgical Implant Generation Network (SIGN) nails.

Methods: Forty-nine patients who fulfilled the inclusion criteria were enrolled prospectively over 8½ years. Data collected included age, sex, injury mechanism and severity, fracture characteristics, nail types and diameter, OD, fracture-to-fixation time, length of hospital stay (LOS), functional outcomes and complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!