A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Numerical Study on the Gas-Solid Flow in a Spouted Bed Installed with a Controllable Nozzle and a Swirling Flow Generator. | LitMetric

The swirling flow technology is adopted on a nozzle of the spouted bed in order to enhance the radial movement of the particles. The hydrodynamic characteristics in a spouted bed with a swirling flow generator installed on the nozzle are numerically investigated based on the two-fluid model (TFM). The traditional spouted bed and spouted bed with an integral swirling blade nozzle (ISBN) are simulated and analyzed. Numerical results show that the dead zone at the cone region of the annulus can be effectively eliminated by using the ISBN. The maximum decrease in particle concentration near the cone region is 72%, and the ISBN structure can significantly improve the comprehensive fluidization degree of the spouted bed when γ equals 86°. The turbulent kinetic energy of gas can be significantly increased by the swirling flow along the radial direction in the spouted bed, especially in the spout region. Also, the swirling flow can promote the radial velocity and granular temperature of the particles in the spouted bed, which is helpful to the radial mixing of particles and gas phase between the central spout and the annulus in the spouted bed. There exists a value of ξ (equals 0.526), which brings the greatest elimination effect of the flow dead zone in the annulus of the limited spouted bed space, and the overall fluidization of the spouted bed has the best performance when ξ = 0.316.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6977066PMC
http://dx.doi.org/10.1021/acsomega.9b02704DOI Listing

Publication Analysis

Top Keywords

spouted bed
44
swirling flow
20
spouted
11
bed
11
flow generator
8
dead zone
8
cone region
8
flow
7
swirling
6
numerical study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!