When used in hospital settings, glucose meter performance issues involve analytic comparability to lab-based testing, patient and sample variables, and clinical affects such as insulin treatment protocol outcomes and morbidity or outcome risk factors. Different tools are available to assess these issues, including accuracy and precision statistics along with clinical risk measures such as error grids or simulation testing. Regulatory, guidance, and professional bodies have advocated a number of varying recommendations for glucose meter performance in different situations and under different patient conditions. These are summarized and compared, but reconciling these guidelines can be confusing or difficult for providers. Blood glucose meters are useful in the management of patients in acute or assisted care facilities, but users must appreciate the variables that affect measurements and provide for oversight that can manage risk factors and maintain meter performance expectations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7576947 | PMC |
http://dx.doi.org/10.1177/1932296819898277 | DOI Listing |
ACS Nano
January 2025
State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China.
The seamless integration of electrocatalysts onto the electrode is crucial for enhancing water electrolyzers, yet it is especially challenging when scaled up to large manufacturing. Despite thorough investigation, there are few reports that tackle this integration through roll-to-roll (R2R) methodology, a technique crucial for fulfilling industrial-scale demands. Here, we develop an R2R flash Joule heating (R2R-FJH) system to process catalytic electrodes with superior performance.
View Article and Find Full Text PDFZhonghua Xin Xue Guan Bing Za Zhi
January 2025
Department of Cardiology, the Second Affiliated Hospital of Nanchang University, Nanchang330006, China.
To compare the impact of manual right arm blood pressure measurement with computer-controlled blood pressure meter (CCBPM) on the detection rate of hypertension among elderly individuals. This was a cross-sectional study. Elderly residents undergoing routine health check-up in a village in Jiangxi Province from April to June 2024 were enrolled.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Plant Experimental Biology, Faculty of Science, Charles University, Viničná 5, 12800, Prague, Czech Republic.
A wide range of portable chlorophyll meters are increasingly being used to measure leaf chlorophyll content as an indicator of plant performance, providing reference data for remote sensing studies. We tested the effect of leaf anatomy on the relationship between optical assessments of chlorophyll (Chl) against biochemically determined Chl content as a reference. Optical Chl assessments included measurements taken by four chlorophyll meters: three transmittance-based (SPAD-502, Dualex-4 Scientific, and MultispeQ 2.
View Article and Find Full Text PDFJ Indian Soc Pedod Prev Dent
October 2024
Department of Pedodontics and Preventive Dentistry, Sardar Patel Post Graduate Institute of Dental and Medical Sciences, Lucknow, Uttar Pradesh, India.
Sensors (Basel)
December 2024
Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Quebec City, QC G1M 2S8, Canada.
Although guidelines are established for performing the six-minute walking test (6MWT), it is not always possible to implement this test in any setting, due to physical and space limitations. Yet, variations in the conditions of the test could be responsible for heterogeneous outcomes. However, the impact of the condition of the 6MWT is not clearly established in literature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!